Operation:
Turn
the panel air supply
ON
. Adjust
the
regulators pressure between 50 and 70PSI
(see Picture #6).
Turn
the
WRAP RETRACT OUTPUT ON
and verify that both brushes are extended in
their ready position (in the center-line of the
wash bay).
Manually
turn the air valve
ON
one at a time
and confirm that each valve is controlling the
appropriate cylinder (
DRIVER’S
or
PASSEN-
GER’S SIDE
).
Manually
turn the
OUTPUT ON
for
EACH
VALVE
and, one at a time, confirm that each
output is controlling the appropriate valve
(
DRIVER’S
or
PASSENGER’S SIDE
) and
that both brushes are moving out (as shown
on picture #7 below).
Pic 7: Test Bump Out