© Motor City Wash Works, Inc. 48285 Frank, Wixom Michigan 48393 U.S.A.
Phone: 248.313.0272 ▪ Fax: 248. 313.0271
8MANLWRPCROVR01 09-16-20
www.motorcitywashworks.com
20
Optional Mirror Bump Air Panel Installation:
Bring
a
3/8” OD
polyflow tubing air line from the main compressed air line to the
AIR PANEL.
Pull one
ORANGE 3/8” OD
from the
PASSENGER’S SIDE REGULATOR
to the
PASSENGER’S SIDE PRIMARY
CYLINDER
and connect to the
ROD END OF THE CYLINDER
(see Picture #34 below).
Pull
one
PURPLE 3/8” OD AIR LINE
from the
DRIVER’S SIDE REGULATOR
to the
DRIVER’S SIDE
PRIMARY CYLINDER
and connect to the
ROD END OF THE CYLINDER
(see Picture #34 below).
Pic #34 Bump Air Panel
Connect
the
DRIVER’S SIDE SOLENOID VALVE
to one
OUTPUT FROM THE CAR WASH
CONTROLLER
and program the output to
TURN ON 12” BEFORE THE FRONT OF THE CAR AND
STAY ON UNTIL THE DRIVER’S SIDE WHEEL HAS PASSED BEYOND THE MIRROR AREA (OR
ABOUT 9’ LONG).
Pic #35 Bump Air Panel 12” Before Front of Car
PASSENGER
3/8" PURPLE AIR LINE
3/8" ORANGE AIR LINE
MAIN AIR INLET
SIDE
DRIVER
SIDE
PASSENGER
SIDE
DRIVER
SIDE