© Motor City Wash Works, Inc. 48285 Frank, Wixom Michigan 48393 U.S.A.
Phone: 248.313.0272 ▪ Fax: 248. 313.0271
8MANLWRPCROVR01 09-16-20
www.motorcitywashworks.com
13
Pic #25 Electrical Schematic
If
you have purchased the
ELECTRIC DRIVE CROSS-OVER™,
connect each
1.5 HP MOTOR
to a
separate starter unit. Each motor has to be protected with an
OVERLOAD RELAY SET AT THE MOTOR
RATED FULL LOAD CURRENT FOR THE PROPER VOLTAGE.
NOTE:
NEITHER OF THE MOTOR ELECTRICAL CABLES ARE
CONNECTED TO THE MOTOR LEADS WHEN
SHIPPED FROM THE MCWW FACTORY.
OPEN THE MOTOR CONNECTION BOXES AND CONNECT THEM
TO THE MOTOR LEADS, FOLLOWING THE APPROPRIATE
CONNECTION DIAGRAM BELOW OR
ON THE MOTOR PLATE (PICTURE #26) FOR PROPER VOLTAGE.
Pic #26 Motor Connection