FOR EXAMPLE:
IF THE PRIMARY ARM AIR CYLINDER REGULATOR IS SET AT
50 PSI
, THEN SET
THE
MIRROR BUMP AIR PANEL REGULATOR AT
30 PSI
. TO DECREASE THE
BRUSH PRESSURE TO THE MIRROR AREA, INCREASE THE REGULATOR TO
35
PSI
.
IF THE PRIMARY ARM AIR CYLINDER REGULATOR IS SET AT
40 PSI
, THEN SET
THE
MIRROR BUMP AIR PANEL REGULATOR AT
20 PSI
. TO DECREASE THE
BRUSH PRESSURE TO THE MIRROR AREA, INCREASE THE REGULATOR TO
25
PSI
.
Foamers Installation:
Bring ONE
1/2" OD and ONE 3/8” OD
polyflow tube from a dilution station to the
MIDDLE OF THE
BOTTOM CROSS BEAM
and connect to the existing push-on fittings (see Picture # 34).
NOTE:
THE DILUTION STATION SHOWN IN
PICTURE #38 IS NOT INCLUDED WITH YOUR
CROSS-OVER™ WRAP AROUND UNIT;
IT CAN BE PURCHASED SEPARATELY THROUGH
YOUR LOCAL MCWW DISTRIBUTOR
(PART# FOAMDLUTNSTN001).
Pic #38 Streamers Air-Solution Lines
3/8" AIR LINE
1/2" SOLUTION LINE