10
Problem
Cause
Correction
Engine is running, but no
AC output is available.
1. Red overload alarm light is on.
Generator is overloaded.
2. Green output indicator light not on.
Fault in generator.
3. Poor connection or defective cord set.
4. Connected device is bad.
1. Remove loads from generator.
Press RESET button on control
panel.
2. Contact authorized dealer.
3. Check and repair.
4. Connect another device that is in
good condition.
Engine runs well at no-load
but “bogs down” when
loads are connected.
1. Generator is overloaded.
1. Remove loads from generator.
Engine will not start; starts
and runs rough or shuts
down when running.
1. Engine switch set to OFF (0) position.
2. Low oil level.
3. Dirty air cleaner.
4. Out of fuel.
5. Spark plug wire not connected to
spark plug.
6. Flooded with fuel.
1. Set switch to ON (I) position.
2. Fill crankcase to proper level or
place generator on level surface.
3. Clean or replace air cleaner.
4. Fill fuel tank.
5. Connect wire to spark plug.
6. Wait 5 minutes and re-crank engine.
For all other issues, see a
MOSA
Authorized Dealer.
Troubleshooting
* Starting Surge represents the momentary electrical current the
generator can provide to start electric motors.
Starting Surge does not represent the power required to continuously run electrical loads. Starting Surge is the maximum
current that can be supplied when starting a motor, multiplied by the generator’s rated voltage.
** Generator per ISO 8528 Performance class G1 Reciprocating internal combustion engine driven alternating current generating
sets.
Product Specifications
Starting Surge* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3,000
Running Watts** . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2,600
Load Current:
at 230 Volts AC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11.3 Amps
at 12 Volts DC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Amps
Rated Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 Hertz
Phase. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Single Phase
Displacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171 cc (10.44 cu. in.)
Spark Plug Gap. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.6-0.7 mm (0.023-0.027 in.)
Fuel Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.7 L (1.5 U.S. gallon)
Oil Capacity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.6 L (20 Ounces)
Содержание GE 3000 BI
Страница 2: ......
Страница 3: ...2 BRIGGSandSTRATTON COM F E P L A G R S N J H C B D T 1 K M...
Страница 4: ...3 2 11 10 B A 8 3 12 C A D B 9 A 6 5 4 D F A E C B 7...
Страница 12: ...11...
Страница 20: ...11...
Страница 28: ...11...
Страница 36: ...11...
Страница 44: ...11...
Страница 52: ...11...
Страница 53: ......