13
2 0 0 8 K n I G h t
lp Gas systems —
LP-Gas is heavier than air and will settle to
the lowest point in the motorhome. The LP-Gas
detector is also sensitive to other fumes such
as hair spray, of which most contain butane as
the propellant. Butane, like propane, is heavier
than air and will settle to the floor level. Sulfated
batteries (rotten egg odor) will also sound the
alarm. When this occurs, reset the detector to
stop the alert sound.
About the LP-Gas Detector:
Be aware of the difference between a leak
versus LP-Gas escaping from an unlit, open
burner. Pure LP-Gas vapors from a leaking pipe
or fitting are heavier than air and will build up
heaviest concentration at the leak and float down
to mix with air. If a burner is left on, the area
around the burner, range and adjoining counter
space is combustible and can cause injury and
damage when ignited. This condition will exist
for an extended time period. Eventually, the LP-
Gas will reach the detector’s location and cause
the alarm to sound.
NOTE
The LP-Gas detector indicates the
presence of LP-Gas only at its sensor.
Combustible levels of LP-Gas may be
present in other areas. The detector is
intended for detection of LP-Gas only.
The LP-Gas detector is not designed to detect
other types of gas. However, some products may
cause the detector to alarm, such as alcohol,
liquor, kerosene, gasoline, deodorants, colognes,
propellant used in spray cans and cleaning
solvents. In some cases, vapors from glue and
adhesive used in the manufacturing of the
motorhome may also cause the detector to alarm
for several months after the date of manufacture.
If it is determined that the detector has false
alarmed because of the above mentioned
nuisance gases, reset the detector and ventilate
the motorhome with fresh outside air. Take
precautions to ensure one of these cases has not
masked an actual LP-Gas alarm condition.
The LP-Gas detector draws less current than
one instrument panel lamp and will detect gas
until the battery is drained down to 7.0 Volts. A
voltage higher than 7.0 Volts is needed for the
detector to operate properly. If the power source
is disconnected, or if the power is otherwise
interrupted, the detector will not operate.
The LP-Gas detector has a self-check circuit
running at all times while the detector is
powered. In the event that the circuitry fails,
a failure alarm will sound and the operating
indicator will cease to light.
The LP-Gas detector is wired to the house
batteries. This allows reliable protecting by
alerting the build up of potentially dangerous
levels of LP-Gas.
WARNING
If the motorhome is unplugged
from shore power, the house battery
disconnect switch must be ON for the
LP-Gas detector to operate.
LP-Gas Detector Operation:
Upon first application of power the LED will
flash yellow for three minutes while the detector
is stabilizing. At the end of the start cycle the
LED will turn Green indicating full operation.
If the detector senses unsafe levels of LP-Gas it
will immediately sound an alarm. The LP-Gas
detector operates on 12 Volt DC, with a current
draw of less than 1/10th of one amp.
CAUTION
The detector will not sound an alarm
during the three minute warm up cycle.
Testing
Press the TEST switch any time during the
warm up cycle or while in normal operation.
The LED will turn red and an alarm will sound.
Release the switch. This is the only way to test
full operation of the detector.
Alarm
The red LED will flash and the alarm will
sound whenever dangerous levels of LP-Gas
or natural gas are detected. The detector will
continue to alarm until the gas clears or the
Test/Mute
switch
is pressed.
Alarm Procedures:
1. Turn off all LP-Gas appliances (stove,
water heater, furnace, refrigerator),
extinguish all flames and smoking
material. Evacuate immediately. Leave
doors and windows open.
030646b
020155e
Содержание 2008 Knight
Страница 12: ......
Страница 14: ......
Страница 16: ......
Страница 46: ...driving safety 2 42 2008 Knight Weighing Procedure Worksheet Example Worksheet 020255b conv...
Страница 47: ...2008 KNight 43 driving safety 2 Weight Record Sheet Actual Worksheet 020255b...
Страница 52: ...driving safety 2 48 2008 Knight Notes...
Страница 76: ...exterior interior care 3 72 2008 Knight Notes...
Страница 190: ...electrical systems chassis 9 186 2008 Knight engine no start flow chart...
Страница 233: ...2008 KNight chassis information 10 229 Notes...
Страница 237: ...2008 KNight chassis information 10 233 Battery Specification Charts...
Страница 246: ......