General InformatIon — 1
2 0 0 8 K n I G h t
Desiccant -
A granular substance that has a
high affinity for water and is used to retain
moisture from the air stream flowing through
the air dryer cartridge.
Direct Current (DC) -
Power that is
stored in a battery bank or supplied by
photovoltaics, alternator, chargers and DC
generators. Direct current is also known as
battery power. Current only flows one way.
Drain Trap -
This is a curve that is in all
drains. Water is trapped in the curve and this
creates a barrier so tank odors cannot escape
through the drain.
Dry Camping -
Camping in the motorhome
when there is no city water hook-up or shore
power. In other words, using only the water
and power that is in the motorhome and not
from another source.
Drying Cycle -
The time during which the
air dryer cools, filters and removes moisture
from the air delivered by the air compressor.
The drying cycle begins and ends the same
as the compressor load cycle.
Dump Station -
A site where the waste
(grey) and sewage (black) tanks can be
drained. In most states it is illegal to drain
waste tanks anywhere other than at a dump
station.
Dump Valve -
Another name for the
T-handle valve used to drain the sewage
(black) and waste (grey) tanks.
Escape (Egress) Window -
The formal
name for the emergency window located in
the rear of the motorhome. Egress windows
can be easily identified by their red handles.
Full Hook-Up Site -
A campground that has
city water, shore power and sewer hook-ups
or connections available.
Grey Water -
Term associated with the
waste water holding tank. Water from the
sink drains, the shower and the washer-dryer
(if equipped) go into this tank.
House Battery -
Powers 12 Volt DC lights
and accessories inside motorhome.
LED (Light Emitting Diode) -
Indicator
light.
Liquid Lead Acid Battery (LLA)
-
A type of battery that uses liquid as an
electrolyte. This type of battery requires
periodic maintenance such as cleaning the
connections and checking the electrolyte
level.
Low Point Drain -
The lowest point in the
plumbing. These drains must be closed when
you fill the water tank.
OEM -
Term for Original Equipment
Manufacturer.
OHM -
A unit for measuring electrical
resistances.
Ohm’s Law -
Expresses the relationship
between Volt (E), amperes (I) in an
electrical circuit with resistance (R). It can
be expressed as follows: E = IR. If any two
of the three values are known, the third
value can be calculated by using the above
formula.
Potentiometer -
A device for measuring
an unknown potential difference or
electromotive force.
Pounds Per Square Inch Gauge (psig) -
Pressure measured with respect to that of the
atmosphere. This is a pressure gauge reading
in which the gauge is adjusted to read zero at
the surrounding atmospheric pressure. It is
commonly called gauge pressure.
Purge -
The initial blast of air
(decompression) from the air dryer purge
valve at the beginning of the air compressor.
Purge Cycle -
The time during which the air
dryer is undergoing purge and regeneration.
This cycle starts at the beginning of the
compressor unload cycle and normally ends
well before the beginning of the compressor
load cycle.
Regeneration -
The mild backflow of air
through the air dryer and out the purge valve
that begins immediately after the purge
and lasts normally 10 to 15 seconds. This
backflow of air, from the air system and
through the air dryer, removes moisture from
the desiccant cartridge and prepares the air
dryer for the next compressor load cycle.
Содержание 2008 Knight
Страница 12: ......
Страница 14: ......
Страница 16: ......
Страница 46: ...driving safety 2 42 2008 Knight Weighing Procedure Worksheet Example Worksheet 020255b conv...
Страница 47: ...2008 KNight 43 driving safety 2 Weight Record Sheet Actual Worksheet 020255b...
Страница 52: ...driving safety 2 48 2008 Knight Notes...
Страница 76: ...exterior interior care 3 72 2008 Knight Notes...
Страница 190: ...electrical systems chassis 9 186 2008 Knight engine no start flow chart...
Страница 233: ...2008 KNight chassis information 10 229 Notes...
Страница 237: ...2008 KNight chassis information 10 233 Battery Specification Charts...
Страница 246: ......