Assembly and Installation - continued
CAUTION
Do not use heavy equipment, such as a hammer, to install the SeVG Plus
actuator as it may damage the actuator housing and lead to failure of the
actuator.
Hold the motor rod end by the flats and use a proper key during tightening
of the valve pin holder to the rod end thread. Permanent damage to the anti
rotation mechanism will occur if the proper tool is not used. See Figure 6-7.
Do not apply force to the motor rod.
CAUTION
Hold the motor
rod by the flats.
Figure 6-7
Motor rod flats
IMPORTANT
Heat the system to allow any plastic to become soft before the assembly is
installed. See “Warning - hot surfaces” on page 6-7.
Ensure that the cooling system is connected.
NOTE
For systems with the water cooled model of the SeVG actuator, the water
lines must be connected. This timing of the step is system dependent, and
it is the responsibility of the integrator.
1. Insert the valve pin into the bottom piece of the valve pin holder.
NOTE
The valve pin should be able to spin freely.
2. Install this assembly onto the top piece of the valve pin holder. Torque to 8
to 10 Nm [6 to 7 ft-lbs]. See “Figure 6-8 Valve pin holder components” on
3. Align the four spacers and insert into the counterbores of the valve disk
6-8