6. If applicable:
Hydraulic Flow Control:
Turn the dial to the maximum value and activate the solenoid valve. The
valve pin open speed should gradually get slower as the setting value
decreases from 10 to 1.
Normally the unit is set for slow down only when opening while closing is
constant speed. If you observe the unit is slowing down on closing then
investigate. It is possible that the unit is malfunctioning or that settings
have been changed.
Valve Pin Position Monitoring
NOTE
The flow control valve is lockable and the key can be used to unlock all
valves.
• Check to ensure the signal indication on controller screen or LED
board matches the valve pin position.
•
Manually activate the actuator to confirm the signal is switching and
stable.
• Check to ensure that:
• the wiring and connection are correct, as per the General Assembly
drawings
• the proximity sensor is mounted properly and that the sensing probe
is also mounted within its sensing distance and in the correct position
• if mechanical limit switch is used, then the switch is being pressed
down properly
System test - continued
8-6
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.
SYSTEM INSTALLATION
FSG2 User Manual