5.20 Water Cooled Gate Insert Installation
CAUTION
Clean all surfaces and dowel holes. Make sure that there is no debris,
burrs, shavings, dust, dirt or any other foreign material.
Check that all mold base dimensions are in accordance with
Mold-Masters
General Assembly drawings.
CAUTION
IMPORTANT
Water cooled gate inserts
cannot
be used in systems with protective
sleeves.
1. Install O-rings to the gate insert.
2. Install support tube to the gate insert. Insert the dowel pin and the screws
(4XSHCSM4).
3. Install dowel pin to the gate insert or support tube.
5-59
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.
ASSEMBLY