4.9 Piston Assembly for Waterless Pneumatic
Actuator
1. Install the two piston seals and the piston guide ring. See Figure 4-7.
Piston guide
ring
Piston seals
Figure 4-7 Install piston seals and guide ring
2. Install valve pin spacers (thickness = 2.1 mm and 2.2 mm) into the piston
bore.
3. Insert valve pin.
4. Install the remaining two valve pin spacers (thickness = 2.0 mm and
2.3 mm) on top of the valve pin. See Figure 4-8.
Valve pin
Spacers
Figure 4-8 Install valve pin and spacers
5. Install the piston top.
CAUTION
Make sure that the O-ring is in good condition.