5.7.4 Install the Thermocouple onto the Nozzle Body
(F3000/4000 nozzles)
NOTE
The F3000/4000 nozzles supplied after September 2000 do not have
nozzle mounted thermocouples. These thermocouples are mounted on
heater sleeves.
1. Insert the thermocouple into the thermocouple slot until it reaches the
bottom of the slot.
2. Bend the thermocouple along the path of the thermocouple groove.
3. Install the thermocouple clip.
5-15