5.15 Waterless Hydraulic and Pneumatic
Actuator Systems
CAUTION
Make sure that a surface grinding of the contact surface of the top
clamp plate is done. This keeps the waterless actuator operating at
recommended temperatures.
CAUTION
CAUTION
Do not include waterless actuators in the hot runner assembly during high-
temperature oven cleaning. This could cause permanent damage to the
actuators’ components.
CAUTION
Valve insert design
Valve disk design
Figure 5-9 Waterless actuator models: valve disk and valve insert
1. Install the valve insert or the valve disk on top of the manifold.
Install valve insert
Install valve disk
Figure 5-10 Install valve insert or valve disk