4.3 Unpacking
WARNING
Make sure the lifting eyebolt, lifting chain and crane are rated to adequately
support the weight. Failure to do so can cause a serious injury.
Make sure the machine has been locked out and tagged out in accordance
to the machines documented procedures. Failure to do so may lead to
serious injury or death.
1. Carefully open the shipping crate and inspect contents. Secure loose
items and check that the system is received in good condition and no
damage occurred during shipment. Remove any documentation or spares
packages and set aside.
2. After removing all restraints, attach the crane to the hoist and carefully
remove the system from the shipping crate.
3. Check that all mold base dimensions are correct and correspond to
Mold-
Masters
General Assembly drawings.
4.4 Cleaning
All nozzles, manifolds and Hot Runner components must be free of the rust
inhibitor applied at the factory.
4. Remove protective covers from all gate seals.
5. Clean all surfaces and dowel holes, ensuring that no debris, burrs,
shavings, dust, dirt or other foreign material which could interfere with
measurements, exists. Ream holes out if necessary.
6. Remove tape from inlet and clean.
4-2