8.2 Pre-Installation
1. Verify all dimensions, tolerances, angles, taps, chamfers, etc. of the mold,
against the engineering and General Assembly drawings.
2. Record values for future reference.
3. Verify centers, depth tolerances, radii against General Assembly
drawings.
NOTE
If the molding elevation is out of tolerance / - 1.0mm of the General
Assembly drawings, a support bushing with extra stock can be ordered
from
Mold-Masters
. This bushing can then be machined from its bottom
face to compensate for the system height difference caused by mold plate
thickness.
8.3 Install Manifold Locator Dowel
4. Using a depth micrometer, verify the dimensions of the manifold locator
pocket to those specified on print.
5. Apply anti-seize compound to screw.
6. Install the manifold locator dowel.
8-2