Table 3-3 Energy Forms, Energy Sources and General Lockout Guidelines
Energy Form
Energy Source
Lockout Guidelines
Electrical Energy
• Power transmission lines
• Machine power cords
• Motors
• Solenoids
• Capacitors
(stored electrical energy)
•
Turn off power at machine first
(i.e., at point of operation switch),
and then at the main disconnect
switch for the machine.
Lock and tag the main
disconnect switch.
• Fully discharge all capacitative
systems (e.g., cycle machine
to drain power from capacitors)
according to the manufacturer’s
instructions.
Hydraulic Energy
• Hydraulic systems
(e.g., hydraulic presses, rams,
cylinders, hammers)
•
Shut off, lock (with chains, built-
in lockout devices, or lockout
attachments) and tag valves.
•
Bleed off and blank lines as
necessary.
Pneumatic Energy
• Pneumatic systems
(e.g.,lines, pressure reservoirs,
accumulators, air surge tanks,
rams, cylinders)
•
Shut off, lock (with chains, built-
in lockout devices, or lockout
attachments) and tag valves.
•
Bleed off excess air.
• If pressure cannot be relieved,
block any possible movement of
machinery.
Kinetic Energy
(Energy of a moving
object or materials.
Moving object may be
powered or coasting)
• Blades
• Flywheels
• Materials in supply lines
• Stop and block machine parts
(e.g. stop flywheels and ensure
that they do not recycle).
• Review entire cycle of
mechanical motion, ensure that
all motions are stopped.
• Block material from moving into
area of work.
• Blank as required.
Potential Energy
(Stored energy that
an object has the
potential to release
due to its position)
• Springs (e.g., in air brake
cylinders)
• Actuators
• Counterweights
• Raised loads
• Top or movable part of a press
or lifting device
• If possible, lower all suspended
parts and loads to the lowest
(rest) position.
• Block parts that might be moved
by gravity.
• Release or block spring energy.
Thermal Energy
• Supply lines
• Storage tanks and vessels
•
Shut off, lock (with chains, built-
in lockout devices, or lockout
attachments) and tag valves.
•
Bleed off excess liquids or gases.
• Blank lines as necessary.
3.6.2 Energy Forms and Lockout Guidelines
3-11
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.
SAFETY
FSG2 User Manual
Содержание Fusion G2
Страница 1: ...version 14 User Manual Original Instructions...
Страница 2: ......
Страница 10: ......
Страница 64: ......