Water Cooled Gate Insert Installation - continued
4. Drop gate insert assembly into the mold pocket. Make sure that the dowel
pin line up with slot on cavity.
5. Install the locking ring, orient the wiring exit slot to the correct direction.
6. Tighten the screws (4XSHCSM10) evenly to press the gate insert into
correct position completely. Tighten it with the required torque. See torque
table for torque specifications.
7. If it is necessary to lift up gate insert assembly, use the lift holes on gate
insert or support tube.