9.8 Check the Oil Bath Level
WARNING
Do not confuse the low pressure oil port with the high pressure oil system
plug.
1. The E-Multi injection unit should be in horizontal or vertical position and
the injection unit moved fully back.
2.
The oil fill port is positioned so that the oil level may be checked with the
E-Multi injection unit mounted vertically, horizontally, or at any angle in
between.
1
2
1. High pressure oil plug
2. Oil fill port
3.
Remove the plug from the fill port. The oil level should be up to the lower
threads of the fill hole.
4. Fill with synthetic gear oil as indicated in Table 9-6 on page 9-3, as
required.
NOTE
For continued warranty support use only approved synthetic gear oil as
specified in Table 9-6.
9.9 Check Lubrication of Linear Guides and
Injection Ball Screws
1.
Reference the installation drawing supplied with your unit for grease fitting
locations.
2.
Ensure the grease fitting is clean.
3.
Place the grease gun to the grease fitting and pump to apply adequate
grease for relubrication. See Table 9-8 on page 9-6 for the amount of
grease appropriate for your unit.
1
2
1. Ball screw grease
nipples
2. Linear guide grease
nipple
9-7
MAINTENANCE
E-Multi User Manual
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.