4. Remove replacement adapter plate shipping bracket, if necessary.
5. With solvent, clean the mating surfaces of the replacement adapter plate,
adapter blocks (if used) and support beam. Wipe with a clean, lint free
cloth.
1
2
3
1. Adapter blocks
2. Adapter plate
3. Support beam
6. Apply a light coat of oil to the contact surfaces.
7. Install the adapter plate and leave the screws loose. If required, install
adapter blocks with the adapter plate.
8. Remove the linear actuator manual access port cover to expose the jam
screw and adjusting screw.
9. Loosen the jam screw on the carriage link. The adjuster screw can then
be turned to move the nozzle so it is flush with the face of the adapter
plate.
1. Linear actuator manual access port
cover (accessed through the integrated
shipping bracket hole)
2. Linear actuator manual access port
cover
1
2
9-11
MAINTENANCE
E-Multi User Manual