3. Number all heaters and thermocouples and note orientation of connectors
and wires. Heaters and thermocouples are numbered starting with #1 at
the housing end of the barrel.
Heater 1
Thermocouples
4. Remove any plastic residue and clean the end of the barrel.
5. Remove any wire ties.
6. Remove the heater connector insert from the connector base.
7. Unscrew the heater wires from the insert.
8. Loosen the lock nut on the strain relief.
9. Pull the heater cable out of the connector base.
10. Remove the connector base.
11. Loosen the heater clamping screw(s).
12. For socket type thermocouples:
a) Remove the thermocouples from their mountings
b) Remove the thermocouple sockets from barrel
13. For nozzle type thermocouples:
a) Remove the thermocouple from their mountings
9-24
E-Multi User Manual
MAINTENANCE