1. In preparation for mounting the E-Multi Radial to the injection molding
machine, clean the stationary platen surface where the E-Multi Radial will
be mounted.
NOTE
The E-Multi Radial is shipped with the injection unit in the horizontal
position.
2. To move the unit to the vertical orientation, remove the screws mounting
the cable tracks to the lower cable track bracket, and remove the two M10
shipping screws.
Remove screws
from both sides
Remove two M10
shipping screws
3.
Slowly start raising the lifting machine, causing the upper “vertical beam”
to rotate around the pivot pin, without lifting the entire E-Multi Radial off
of the crate floor. Continue this process until the vertical beam is vertical,
and the 2 machined faces are in contact.