7.5 Air Connections
WARNING
Hoses fitted to the E-Multi injection unit will contain high or low temperature
air under high pressure. The operator must shut down and lockout these
systems as well as relieving any pressure before performing any work with
these hoses.
CAUTION
Using compressed air at pressures higher than 4.13 bar (60 PSI) will
drastically shorten the life of the pneumatic vibrator. Damage to the vibrator
as a result of using air pressure over 4.13 bar (60 PSI) is not covered under
warranty.
CAUTION
1.
Install a 1/8NPT fitting (customer supplied) into the vibrator needle valve.
2. Connect a clean, dry, non-lubricated air supply, not exceeding 4.13 bar
(60 PSI), to the vibrator needle valve.
Vibrator needle valve
3. Open the air supply slowly, check for leaks and correct if necessary.
7-5
SYSTEM SETUP
E-Multi User Manual
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.