29. Connect the motor cables to screw and injection motors. Motors and
cables are clearly marked. Make sure that you connect the correct cables
to the correct motors.
30. Secure the motor cables to the upper cable track bracket with cable ties.
Make sure that the cables do not contact the injection housing when the
injection housing moves.
31. Connect the pressure transducer cable to the pressure transducer on the
injection housing.
32. Connect cooling lines to the manifold on the injection housing.
33. Connect carriage motor cables to carriage motor. Make sure that the
cables do not interfere with the cable track and do not bind against the
support beam. Verify once again when the system operates.
34. Remove the maintenance pin from the shipping position in support beam
and install in storage position. Make sure that the pin does not interfere
with cable track.
ER3 / ER4 Installation - continued
11-24
E-Multi User Manual
E-MULTI RADIAL OPTION