99
-
'16 • SCM-T-199
10.
HOW
T
O
REMOVE
AND
INST
ALL
FRONT
P
ANEL
11.
INST
ALLING WIRELESS REMOTE CONTROL
Removing
(1) Remove the 2 screws. (2) Remove the 3 upper latches and then front
panel can be removed.
Installing
(1)
Cover
the
unit
with
the
front
panel
and
fix
3
upper latches.
(2) Secure the front panel with the 2 screws.
Mount the batteries
(1) Slide and take out the cover of backside. (2) Mount the batteries [R03 (AAA, Micro),
×2
pieces] in the body properly
.
(Fit
he
poles
with
the
indication
marks
+
&
−)
(3) Set the cover again.
NOTE
•
Do not use new and old batteries together
.
•
In case the unit is not operated for a long time, take out the batteries
Installing remote control holder
(1) Select the place where the unit can
receive signals.
(2) Fix the holder to pillar or wall with wood
screws.
Batter
y
Co
ver
W
ood scre
ws
ø3.5 X 16
Wireless remote contro
l
12.
INST
ALLING
TWO
AIR-CONDITIONERS
IN
THE
SAME
ROOM
In case two air-conditioners are installed in the same room, apply this setting so that one unit can be operated with only one wireless remote control.
Setting one wireless remote control
(1) Slide and take out the cover and batteries. (2) Cut the switching line next to the battery with
wire cutters.
(3) Set the batteries and cover again.
Cut
Setting one indoor unit
(1) Remove the front panel. (2) Remove the control cover
. (Remove the
screw
.)
(3) Cut jumper wire J2 (marked CUST
OM
on the PCB) on the indoor control board. Do not allow the cut wires to contact any other wiring.
(4) Install the control box and front panel.
Control co
ve
r
Scre
w
Jumper wire (J2) custom
13. PUMP
DOWN WORK
For the environmental protection, be sure to pump down when relocating or disposing of the unit.
Pump down is the method of recovering refrigerant from the indoor unit to the outdoor unit before the connecting pipes are remo
ved from the unit.
When pump down is carried out, forced cooling operation is needed.
Forced cooling operation
(1)
Turn of
f the power source and turn it on again after 1 miniute.
(2) Press the ON/OFF button continuously for at least 5 seconds.
Then operation will start.
For the detail of pump down, refer to the installation manual of outdoor unit.
Unit ON/OFF button
Set scre
ws
Latches
Содержание SCM40ZS-S
Страница 114: ...113 16 SCM T 199 source PJA012D783...
Страница 200: ...199 16 SCM T 199 4 Troubleshooting procedure If the air conditioner runs NO NO NO NO YES YES YES YES 200 201 207 201 207...
Страница 285: ...284 16 SCM T 199 B PJZ012D077 2 Model RC EX1A eco touch REMOTE CONTROL RC EX1A INSTALLATION MANUAL...
Страница 311: ...310 16 SCM T 199 4 10 5 Superlink E board SC ADNA E F SL2NA E and SL4 AE BE to control...
Страница 312: ...311 16 SCM T 199...