'16 • SCM-T-199
2.
SELECTING
INST
ALLA
TION
LOCA
TION
After getting customer
’s approval, select installation location according to following guidelines.
1. Indoor unit
•
Where
there
is
no
obstruction
to
the
airflow
and
where
the
cooled
and
heated
air
can
be
evenly
distributed.
•
A solid place where the unit or the wall will not vibrate.
•
A place where there will be enough space for servicing. (Where space mentioned on the right side can be secured.)
•
Where it is easy to conduct wiring and piping work.
•
A place where unit is not directly exposed to sunlight or street light.
•
A place where it can be easily drained.
•
A place separated at least 1m away from the television or the radio. (T
o prevent interference to im
-
ages and sounds.)
•
A place where this unit is not af
fected by the high frequency equipment or electric equipment.
•
Avoid installing this unit in place where there is much oil mist.
•
A place where there is no electric equipment or household.
•
Install
the
indoor
unit
on
the
wall
where
the
height
from
the
floor
to
the
bottom
of
the
unit
is
more
than
180 cm.
2.
W
ireless
remote
control
•
A place where the air-conditioner can receive the signal surely during operating the wireless remote control.
•
A place where it is not af
fected by the
TV and radio etc.
•
Do not place where it is exposed to direct sunlight or near heat devices such as a stove.
Wireless remote contro
l
Remote control holder
Wood screws
Installation boar
d
6.5 cm minimum from the ceiling
(a) Sleev
e
180 cm minimum from the floor
10 cm minimum
from the wall
5 cm minimum from the wall
3. INST
ALLING INST
ALLA
TION BOARD
•
Installation board should be installed on the wall which can support the weight of the indoor unit.
•
Adjustment
of
the
installation
board
in
the
horizontal
direction
is
to
be
conducted
with
five
screws
in
a
temporary
tightened state.
•
With the standard hole as a center
, adjust the board and level it.
Bolt (M6X12)
In
case
of
fixing
the
unit
on
concrete
wall,
use
nut
anchor.
Mating mar
k
fo
r
le
vel surf
ace
Le
vel position (2 locations)
394
Standard hole
190
40.1
47
130.5
508
130.
5
157
455
157
187.5
394
187.
5
47
7.6
247.5
6.9
65Space
50
service
100
55
Piping for Gas 359.
5
Piping for Liquid 427.
5
Drain hose 530 (ø65)
Unit: mm
55
Installation boar
d
indoor uni
t
Space fo
r
service
Space fo
r
for service
15 Space
for service
Piping hole (ø65)
Piping hole (ø65)
CAUTION
Improper adjustment of the installation board can cause water leakage.
Содержание SCM40ZS-S
Страница 114: ...113 16 SCM T 199 source PJA012D783...
Страница 200: ...199 16 SCM T 199 4 Troubleshooting procedure If the air conditioner runs NO NO NO NO YES YES YES YES 200 201 207 201 207...
Страница 285: ...284 16 SCM T 199 B PJZ012D077 2 Model RC EX1A eco touch REMOTE CONTROL RC EX1A INSTALLATION MANUAL...
Страница 311: ...310 16 SCM T 199 4 10 5 Superlink E board SC ADNA E F SL2NA E and SL4 AE BE to control...
Страница 312: ...311 16 SCM T 199...