(a)
AIR SELECTION button can switch between the combination of upper and lower air outlets and upper air outlet. Not
operable while the air-conditioner is OFF.
(i) Each time the AIR SELECTION button is pressed. The combination of the
upper and lower air outlets and the upper air outlet can be switched.
(ii) When the upper air outlet is selected, AIR OUTLET SELECTION light on
the unit display area will light green.
AIR OUTLET SELECTION
light : OFF
AIR OUTLET SELECTION
light : ON
Upper air outlet
Upper and lower air outlets
AIR SELECTION button
(b) Auto air outlet selection
(i) COOL, DRY operation
1) In case both lower and upper outlets operation is selected in COOL or DRY
operation, both outlets will be kept for sixty minutes after the start or until
indoor temperature is below the setting point. And then the air outlet will change
to the upper outlet. That state will be maintained until switch is turned off.
2) In case both outlets operation with auto fan speed mode is selected, the upper
outlet will be kept for ten minutes after the start or until indoor temperature is
close to reaching the setting point . And then the air outlet will change to both
outlets in order to spread comfort air to every corner.
(ii) HEAT operation
1) In case both lower and upper outlets operation with auto fan speed mode is
selected, the lower outlet will be kept for twenty minutes after the start or until
indoor temperature is close to reaching the setting point . And then the air outlet will
change to both outlets. That state will be maintained until the switch is turned off.
2) Automatic adjustment of lower air outlet direction prevents stirring up of
warm air and keeps optimum comfort at floor level.
(8) Air outlet selection (SRF series only)
(9) 3D auto operation (SRK series only)
Control the flap and louver by 3D AUTO button on the wireless remote control.
Fan speed and air flow direction are automatically controlled, allowing the entire indoor to efficiently conditioned.
(a)
During cooling and heating (Including auto cooling and heating)
(i)
Air flow selection is determined according to room temperature and setting temperature.
Cooling
Air flow selection
Operation mode
AUTO
HI
MED
LO
Heating
Room temp. – Setting temp. >5°C
Setting temp. – Room temp. >5°C
HIGH POWER
AUTO
HI
MED
LO
ULO
ULO
HIGH POWER
AUTO
Room temp. – Setting temp. 5°C
Setting temp. – Room temp. 5°C
<
=
<
=
-
142
-
'16 • SCM-T-199
Содержание SCM40ZS-S
Страница 114: ...113 16 SCM T 199 source PJA012D783...
Страница 200: ...199 16 SCM T 199 4 Troubleshooting procedure If the air conditioner runs NO NO NO NO YES YES YES YES 200 201 207 201 207...
Страница 285: ...284 16 SCM T 199 B PJZ012D077 2 Model RC EX1A eco touch REMOTE CONTROL RC EX1A INSTALLATION MANUAL...
Страница 311: ...310 16 SCM T 199 4 10 5 Superlink E board SC ADNA E F SL2NA E and SL4 AE BE to control...
Страница 312: ...311 16 SCM T 199...