22
(1) Module status and LED status
The following table lists the correspondence between the module status and the LED status.
*1
Either of ON, Flashing, or OFF.
*2
Either of ON or OFF.
*3
When the module is failed, the LED may not turn on.
Module status
Data link
status
LED status
PW
LED
RUN
LED
MODE
LED
D LINK
LED
ERR.
LED
ALM
LED
O/G
LED
Normal mode
Disconnecting
Disconnection
ON
ON
ON
OFF
OFF
OFF
OFF
Link in progress
Data link in
operation
ON
ON
ON
ON
OFF
OFF
OFF
Reserved station
specification in
progress
Cyclic stop
ON
ON
ON
Flashing
OFF
OFF
OFF
Link stop
Cyclic stop
ON
ON
ON
Flashing
OFF
OFF
OFF
Offset/gain setting mode
-
ON
OFF
OFF
OFF
OFF
OFF
ON
Unit test
In progress
-
ON
ON
Flashing
*1
OFF
OFF
OFF
Normal
completion
-
ON
ON
OFF
OFF
OFF
OFF
OFF
Abnormal
completion
-
ON
ON
OFF
OFF
ON
OFF
OFF
Communication error
Cyclic stop
ON
ON
ON
Flashing
ON
OFF
OFF
Error
Major error
-
ON
OFF
*2
*1
ON
*3
*1
OFF
Moderate error
-
ON
ON
*2
*1
ON
*1
OFF
Warning
Minor error
-
ON
ON
*2
*1
Flashing
*1
OFF
Alarm
Alert
-
ON
ON
ON
*1
*1
ON
OFF
Out-of-range
digital value
error
-
ON
ON
ON
*1
*1
Flashing
OFF