App. - 13 App. - 13
APPENDIXES
Address
Decimal (Hex)
Protocol
CH1 CH2
Application
Name
Initial
value
MC Non Bi Pd
Registration
Reference
8260
(2044
H
)
8516
(2144
H
)
Transmission pointer designation (For fixed cycle transmission and
data transmission)
0: No designation
1 to 100: Output head point (send from the nth)
Send the user frames designated in the following transmission
frame No. designation areas from the designated pointer position.
(addresses: CH1 side = BA
H
to 11D
H
, CH2 side = 15A
H
to 1BD
H
)
Output count designation (for fixed cycle transmission and data
transmission)
8261
(2045
H
)
8517
(2145
H
)
0: No designation
1 to 100:Output count (designate the number of frame transmissions.)
— R
Data No. for connection designation (for fixed cycle transmission)
8262
(2046
H
)
8518
(2146
H
)
For designation
of programmable
controller CPU
monitoring
function
0: No designation
0BB8
H
to 0BD5
H
, 8001
H
to 801F
H
: Data No. for connection
0
R
— Allowed
User's Manual
(Application)
8263 to
8268
(2047
H
to
204C
H
)
8519 to
8524
(2147
H
to
2149
H
)
Use prohibited
System area
—
Number of registered word blocks designation
8269
(204D
H
)
8225
(214D
H
)
0 : No designation
1 to 10: Number of blocks of word devices
Number of registered bit blocks designation
8270
(204E
H
)
8226
(214E
H
)
0 : No designation
1 to 10: Number of blocks of bit devices
It is possible to
designate a
maximum of 10
blocks in total.
Programmable controller
CPU abnormal monitoring designation
8271
(204F
H
)
8527
(214F
H
)
0: Do not monitor.
1: Monitor.
Monitoring device designation
8272
(2050
H
)
8528
(2150
H
)
0: No designation
90
H
to CC
H
: Device code
Head device No. designation
8273 to
8274
(2051
H
to
2052
H
)
8529 to
8530
(2151
H
to
2152
H
)
0 or more: Head device No.
Read point designation
8275
(2053
H
)
8531
(2153
H
)
0: No designation
1 or more: Number to read points
Monitoring condition designation (judgment condition
designation)
8276
(2054
H
)
8532
(2154
H
)
0: No designation
1 or more: Monitoring condition
Monitoring condition value designation
8277
(2055
H
)
8533
(2155
H
)
At bit device 0: OFF 1: ON
At word device 0 to FFFF
H
: Monitoring condition value
R
8278
(2056
H
)
8534
(2156
H
)
Transmission pointer designation (for condition
agreement transmission and nonprocedural data
transmission)
0: No designation
1 to 100: Output head point (send from nth)
Send the user frames designated in the following
transmission frame No. designation areas from the
designated pointer position.
(address: CH1 side = BAH to 11DH, CH2 side = 15AH
to 1BDH)
Output count designation (for condition agreement
transmission and nonprocedural data transmission)
8279
(2057
H
)
8535
(2157
H
)
1 to 100: Output count (designate the number
of frame transmissions)
— R
Data No. for connection designation (for condition
agreement transmission)
8280
(2058
H
)
8536
(2158
H
)
No. 1
block
monitoring
device
0BB8
H
to 0BD5
H
, 8001
H
to 801F
H
: Data No. for
connection
0
R
— Allowed
User's Manual
(Application)
8281 to
8361
(2059
H
to
20A9
H
)
8537 to
8617
(2159
H
to
21A9
H
)
For designation
of programmable
controller CPU
monitoring
function
Block
monitoring
devices
No. 2 to
10
The structure of each area is the same as the first block monitoring device area
Refer to *1 for the details of each area.
Allowed
User's Manual
(Application)
8362 to
8421
(20AA
H
to
20E5
H
)
8618 to
8677
(21AA
H
to
21E5
H
)
Use prohibited
System area
—
Содержание MELSEC LJ71C24
Страница 1: ......
Страница 2: ......
Страница 18: ...A 16 A 16 INDEX REVISIONS WARRANTY...
Страница 22: ...A 20 A 20 2 LJ71C24 R2 LJ71C24 R2 Before Using the Product...
Страница 23: ...A 21 A 21 MEMO...
Страница 38: ...4 2 4 2 4 PROCEDURES PRIOR TO OPERATION MEMO 4...
Страница 105: ...7 30 7 30 7 SETTINGS FOR THE C24 MEMO...
Страница 391: ...App 62 App 62 APPENDIXES 3 Refresh parameter setting In Refresh Parameter set the following network parameters...
Страница 425: ......
Страница 426: ......
Страница 427: ......