App. - 8 App. - 8
APPENDIXES
Address
Decimal (Hex)
Protocol
CH1 CH2
Application Name
Initial
value
MC Non Bi Pd
Registration
Reference
Switch setting error and mode switching error status
0: No error
Other than 0: Switch setting error and mode switching error
515
(203
H
)
For confirmation
of switch setting
and mode
switching
CH1 Communication protocol setting No. (b0)
0: Normal 1: Error
CH1 Communication rate setting (b1)
0: Normal 1: Error
CH1 Setting change prohibit time mode switching (b3)
0: Normal 1: Error
CH2 Communication protocol setting No. (b4)
0: Normal 1: Error
CH2 Communication rate setting (b5)
0: Normal 1: Error
CH2 Setting change prohibit time mode switching (b7)
0: Normal 1: Error
Setting station No. (b14)
0: Normal 1: Error
Linked operation setting (b15)
0: Normal 1: Error
0 R
Not allowed
Section 7.3
Section 15.1.1
Section 15.1.5
Number of registered user frames
516
(204
H
)
0: No registration
1 to 200: Number of registered frames
User frame registration status (for confirmation of registration No.)
0: No registration
1: Registered
517 to 541
(205
H
to 21D
H
)
Bit corresponding to registration No. is 0(OFF)/1(ON).
Registration No.3E8
H
(1000) : Address 205
H
(b0) to
Registration No. 4AF
H
(1199) : Address 211
H
(b7)
—
542
(21E
H
)
For confirmation
of user frame
Number of registered default registration frames (for system)
Depen
ds on
registra
tion
status
R —
Not
allowed
User's Manual
(Application)
543
(21F
H
)
Use prohibited
System area
—
Flash ROM system parameters write result
544
(220
H
)
For confirmation
of flash ROM
write result
0 : Normal completion
Other than 1 (error code) : Abnormal completion
RW Not
allowed
—
Modem function error code (error code when modem function is
being used)
RW
545
(221
H
)
0 : Normal completion
Other than 1 (error code) : Abnormal completion
Modem function sequence status
546
(222
H
)
0: Idle
1: Waiting for initialization
2: Initializing modem
3: Waiting
4: Checking password
5: Communicating
7: Modem disconnected
8: Callback Request reception waiting
9: Callback Modem disconnect
waiting
10: Callback Delay time waiting
11: Callback Reconnecting
12: Callback Rechecking password
0
Number of data registration for connection
547
(223
H
)
0: No registration
1 to 30: Number of registrations
Data registration status for connection
(for confirmation of registration No.)
0: No registration
1: Registered
548 to 549
(224
H
to 225
H
)
Bit corresponding to registration No. is 0(OFF)/1(ON).
Registration No. BB8
H
(3000) : Address 224
H
(b0) to
Registration No. BD5
H
(3029) : Address 225
H
(b13)
Number of data registration for initialization
550
(226
H
)
0: No registration
1 to 30: Number of registrations
Data registration status for initialization
(for confirmation of registration No.)
0: No registration
1: Registered
551 to 552
(227
H
to 228
H
)
For confirmation
of modem
function
Bit corresponding to registration No. is 0(OFF)/1(ON).
Registration No.9C4H (2500) : Address 227H (b0) to
Registration No. 9E1H (2529) : Address 228H (b13)
Depen
ds on
registra
tion
status.
R
—
Not allowed
User's Manual
(Application)
553 to 590
(229
H
to 24E
H
) Use prohibited
System area
—
Содержание MELSEC LJ71C24
Страница 1: ......
Страница 2: ......
Страница 18: ...A 16 A 16 INDEX REVISIONS WARRANTY...
Страница 22: ...A 20 A 20 2 LJ71C24 R2 LJ71C24 R2 Before Using the Product...
Страница 23: ...A 21 A 21 MEMO...
Страница 38: ...4 2 4 2 4 PROCEDURES PRIOR TO OPERATION MEMO 4...
Страница 105: ...7 30 7 30 7 SETTINGS FOR THE C24 MEMO...
Страница 391: ...App 62 App 62 APPENDIXES 3 Refresh parameter setting In Refresh Parameter set the following network parameters...
Страница 425: ......
Страница 426: ......
Страница 427: ......