13 - 6 13 - 6
13 DEBUG SUPPORT FUNCTION
3. In the "Circuit Trace Option" screen, set "Start Address", "Size", and "Stop
Setting" of the monitor buffer area, and click the OK button.
[Display/Setting details]
Item Display/Setting
details
Circuit Trade Data Storage Area Setting
—
Start Address
Set the starting address of the monitor buffer area.
Input the setting in hexadecimal.
•
Input range
CH1/CH2: 2600
H
to 3FFD
H
(C00
H
to 1AFD
H
for the user setting area)
Size
Set the size of the monitor buffer area.
Input the setting in hexadecimal.
•
Input range
CH1/CH2: 3 to 1A00 words (3 to F00 words for the user setting area)
Set the maximum address
1
for the trace data storage space to be in the
range between 2602
H
to 3FFF
H
. (C02
H
to 1AFF
H
for the user setting area)
Note that the range of this value is checked at start of the circuit trace
when using the user free area.
Stop Setting
—
Stop by occurrence of timer 0 time-out
error
Set whether or not the circuit trace is stopped when the timer 0 time out
error occurs.
1 The maximum address for the trace data storage space is calculated by the following formula.
Maximum address for the trace data storage space = "Start Address" + "Size" – 1
Содержание MELSEC LJ71C24
Страница 1: ......
Страница 2: ......
Страница 18: ...A 16 A 16 INDEX REVISIONS WARRANTY...
Страница 22: ...A 20 A 20 2 LJ71C24 R2 LJ71C24 R2 Before Using the Product...
Страница 23: ...A 21 A 21 MEMO...
Страница 38: ...4 2 4 2 4 PROCEDURES PRIOR TO OPERATION MEMO 4...
Страница 105: ...7 30 7 30 7 SETTINGS FOR THE C24 MEMO...
Страница 391: ...App 62 App 62 APPENDIXES 3 Refresh parameter setting In Refresh Parameter set the following network parameters...
Страница 425: ......
Страница 426: ......
Страница 427: ......