![Mitsubishi GOT2000Series Скачать руководство пользователя страница 286](http://html1.mh-extra.com/html/mitsubishi/got2000series/got2000series_connection-manual_1809187286.webp)
11 - 6
11. CONNECTION TO GE PLC
11.2 System Configuration
11.2.2
Connecting to Series90-70
POINT
POINT
POINT
Only the models that are compatible with SNP-X protocol can be connected.
For the RS-232 connection
*1
Product manufactured by GE Corporation.
For details of the product, contact GE Corporation.
For the RS-422 connection
*1
Product manufactured by GE Corporation.
For details of the product, contact GE Corporation.
*2
Including the cable length of the option devices.
*3
Connect it to the RS-232 interface (built into GOT). It cannot be mounted on GT1655 and GT155
.
Series
90-70
Communication
Modules
GOT
Connection cable
POWER SUPPLY
LOGIC POWER
PROGRAMMABLE
CONTROLLER
OK
RUN
EN
CENTRAL
PROCESSOR
UNIT
MEM PROTECT
P1
P2
P3
OK
PORT 1
PORT 2
COMMUNICATIONS
COPROCESSOR
GE (SNP-X)
Communication driver
PLC
Connection cable
GOT
Number of
connectable
equipment
Model name
Communication
Modules
*1
Communi
cation
Type
Cable model
Connection diagram
number
Max.
distance
Option device
Model
IC697CPX772
IC697CPX782
IC697CPX928
IC697CPX935
IC697CPU780
IC697CPU788
IC697CPU789
IC697CPU731
IC697CGR772
IC697CGR935
IC697CPM790
IC697CMM711
RS-232
15m
- (Built into GOT)
1 PLC for 1 GOT
GT15-RS2-9P
Series
90-70
Communication
Modules
GOT
Connection cable
-----
POWER SUPPLY
LOGIC POWER
PROGRAMMABLE
CONTROLLER
OK
RUN
EN
CENTRAL
PROCESSOR
UNIT
MEM PROTECT
P1
P2
P3
OK
PORT 1
PORT 2
COMMUNICATIONS
COPROCESSOR
POWER SUPPLY
LOGIC POWER
PROGRAMMABLE
CONTROLLER
OK
RUN
EN
CENTRAL
PROCESSOR
UNIT
MEM PROTECT
P1
P2
P3
OK
PORT 1
PORT 2
COMMUNICATIONS
COPROCESSOR
POWER SUPPLY
LOGIC POWER
PROGRAMMABLE
CONTROLLER
OK
RUN
EN
CENTRAL
PROCESSOR
UNIT
MEM PROTECT
P1
P2
P3
OK
PORT 1
PORT 2
COMMUNICATIONS
COPROCESSOR
GE (SNP-X)
Communication driver
PLC
Connection cable
GOT
Number of
connectable
equipment
PLC
Communication
Modules
*1
Communi
cation
Type
Cable model
Connection diagram
number
Max.
distance
Option device
Model
IC697CPX772
IC697CPX782
IC697CPX928
IC697CPX935
IC697CPU780
IC697CPU788
IC697CPU789
IC697CPU731
IC697CGR772
IC697CGR935
IC697CPM790
IC697CMM711
RS-422
1200m
- (Built into GOT)
Up to 8 PLCs for
1 GOT
GT15-RS4-9S
Содержание GOT2000Series
Страница 2: ......
Страница 17: ...A 15 REVISIONS WARRANTY...
Страница 52: ...1 30 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring...
Страница 54: ......
Страница 78: ...3 10 3 CONNECTION TO HITACHI PLC 3 6 Device Range that Can Be Set...
Страница 100: ...4 22 4 CONNECTION TO FUJI PLC 4 7 Precautions...
Страница 174: ...7 24 7 CONNECTION TO YOKOGAWA PLC 7 4 Device Range that Can Be Set...
Страница 262: ...9 54 9 CONNECTION TO RKC TEMPERATURE CONTROLLER 9 7 Precautions...
Страница 280: ...10 18 10 CONNECTION TO ALLEN BRADLEY PLC 10 4 Device Range that Can Be Set...
Страница 296: ...11 16 11 CONNECTION TO GE PLC 11 7 Precautions...
Страница 308: ...12 12 12 CONNECTION TO LS INDUSTRIAL SYSTEMS PLC 12 6 Device Range that Can Be Set...
Страница 332: ...14 18 14 CONNECTION TO SIEMENS PLC 14 4 Device Range that Can Be Set...
Страница 334: ...REVISIONS 2...
Страница 337: ......