6. CONNECTION TO YASKAWA PLC
6.3 Ethernet Connection
6 - 19
6
CONNECTION T
O
Y
A
SK
A
W
A PLC
6.3.3
GOT Ethernet setting
Ethernet setting
*1
Connection with the PLC is unavailable if the IP address is
the default value. Set the value to the IP address of the PLC
to be connected.
Item
Description
Range
GOT
IP Address
Set the IP address of the GOT.
(Default: 192.168.0.18)
0.0.0.0 to
255.255.255.255
Subnet
Mask
Set the subnet mask for the sub
network.(Only for connection via
router)
If the sub network is not used, the
default value is set.
(Default: 255.255.255.0)
0.0.0.0 to
255.255.255.255
Default
Gateway
Set the router address of the
default gateway where the GOT is
connected.(Only for connection via
router)
(Default: 0.0.0.0)
0.0.0.0 to
255.255.255.255
Peripheral S/W
Communication
Port No.
Set the GOT port No. for the S/W
communication. (Default: 5015)
1024 to 5010
5014 to 65534
(Except for 5011,
5012, 5013 and
49153)
Transparent Port
No.
Set the GOT port No. for the
transparent function.
(Default: 5014)
1024 to 5010
5014 to 65534
(Except for 5011,
5012, 5013 and
49153)
Item
Description
Set value
Host
The host is displayed. (The host is
indicated with an asterisk (*).)
―
Net No.
Set the network No. of the
connected Ethernet module.
(Default: blank)
1 to 239
Station
Set the station No. of the
connected Ethernet module.
(Default: blank)
1 to 64
Type
YASKAWA (fixed)
YASKAWA (fixed)
IP address
*1
Set the IP address of the
connected Ethernet module.
(Default: blank)
PLC side IP
address
Port No.
Set the port No. of the connected
Ethernet module.
(Default: 10500)
256 to 65534
Communication
format
Select a communication protocol.
(Default: UDP)
UDP, TCP
Содержание GOT2000Series
Страница 2: ......
Страница 17: ...A 15 REVISIONS WARRANTY...
Страница 52: ...1 30 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring...
Страница 54: ......
Страница 78: ...3 10 3 CONNECTION TO HITACHI PLC 3 6 Device Range that Can Be Set...
Страница 100: ...4 22 4 CONNECTION TO FUJI PLC 4 7 Precautions...
Страница 174: ...7 24 7 CONNECTION TO YOKOGAWA PLC 7 4 Device Range that Can Be Set...
Страница 262: ...9 54 9 CONNECTION TO RKC TEMPERATURE CONTROLLER 9 7 Precautions...
Страница 280: ...10 18 10 CONNECTION TO ALLEN BRADLEY PLC 10 4 Device Range that Can Be Set...
Страница 296: ...11 16 11 CONNECTION TO GE PLC 11 7 Precautions...
Страница 308: ...12 12 12 CONNECTION TO LS INDUSTRIAL SYSTEMS PLC 12 6 Device Range that Can Be Set...
Страница 332: ...14 18 14 CONNECTION TO SIEMENS PLC 14 4 Device Range that Can Be Set...
Страница 334: ...REVISIONS 2...
Страница 337: ......