9. CONNECTION TO RKC TEMPERATURE CONTROLLER
9.2 System Configuration
9 - 9
C
O
NN
ECTION T
O
RK
C TEMPE
R
A
T
UR
E CON
T
R
O
LLER
9
9.2.3
Connecting to SRZ
When connecting to temperature control module (Z-TIO, Z-CT) with a converter
*1
Product manufactured by DATA LINK Co.,Ltd. For details of the product, contact DATA LINK Co.,Ltd.
When connecting directly to temperature control module (Z-TIO, Z-CT)
*1
Including the cable length of the option devices.
*2
Product manufactured by MITSUBISHI ELECTRIC ENGINEERING COMPANY LIMITED. For details of the product, contact
MITSUBISHI ELECTRIC ENGINEERING COMPANY LIMITED.
GOT
Interface
converter
Connection cable 1)
Connection cable 2)
SRZ
SRZ
RKC
SR Mini HG(MODBUS)
Communication driver
Temperature
controller
Connection cable 1)
Converter
Connection cable 2)
GOT
Number of
connectable
equipment
Series
Cable model
Connection
diagram number
Max.
distance
Model
name
Communication
Type
Cable model
Connection
diagram number
Max.
distance
Option device
Model
SRZ
1200m
CD485/V
*1
RS-232
15m
-
(Built into GOT)
Z-TIO: Up to 16
Z-CT: Up to 16
Z-DIO: Up to 16
Total of Z-TIO, Z-
CT and Z-DIO: Up
to 31 for 1 GOT
GT15-RS2-9P
SRZ SRZ
GOT
Connection cable
RKC
SR Mini HG(MODBUS)
Communication driver
Temperature controller
Connection cable
GOT
Number of connectable equipment
Series
Communication
Type
Cable model
Connection diagram
number
Max.
distance
Option device
Model
SRZ
RS-485
1200m
- (Built into GOT)
Z-TIO: Up to 16
Z-CT: Up to 16
Z-DIO: Up to 16
Total of Z-TIO, Z-CT and Z-DIO:
Up to 31 for 1 GOT
1200m
*1
FA-LTBGT2R4CBL05(0.5m)
*2
FA-LTBGT2R4CBL10(1m)
*2
FA-LTBGT2R4CBL20(2m)
*2
1200m
GT15-RS4-TE
Содержание GOT2000Series
Страница 2: ......
Страница 17: ...A 15 REVISIONS WARRANTY...
Страница 52: ...1 30 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring...
Страница 54: ......
Страница 78: ...3 10 3 CONNECTION TO HITACHI PLC 3 6 Device Range that Can Be Set...
Страница 100: ...4 22 4 CONNECTION TO FUJI PLC 4 7 Precautions...
Страница 174: ...7 24 7 CONNECTION TO YOKOGAWA PLC 7 4 Device Range that Can Be Set...
Страница 262: ...9 54 9 CONNECTION TO RKC TEMPERATURE CONTROLLER 9 7 Precautions...
Страница 280: ...10 18 10 CONNECTION TO ALLEN BRADLEY PLC 10 4 Device Range that Can Be Set...
Страница 296: ...11 16 11 CONNECTION TO GE PLC 11 7 Precautions...
Страница 308: ...12 12 12 CONNECTION TO LS INDUSTRIAL SYSTEMS PLC 12 6 Device Range that Can Be Set...
Страница 332: ...14 18 14 CONNECTION TO SIEMENS PLC 14 4 Device Range that Can Be Set...
Страница 334: ...REVISIONS 2...
Страница 337: ......