7 - 14
7. CONNECTION TO YOKOGAWA PLC
7.2 Serial Connection
4.
Select "Reboot (Online Mode)" on the "Reboot"
screen of the FCX Maintenance Page to set the online
mode.
Defining Logic POU
Define Logic POU using Logic Designer (peripheral
software), and download the project to STARDOM.
1.
Start Logic Designer and create a new project using a
template.
Use [STARDOM Serial Communication] template.
2.
Insert FA-M3 Emulator Firmware Library to the new
project.
(1) Right-click [Library] under the project tree in Logic
Designer.
(2) Right-click [Insert] and select [Firmware Library].
(3) Double-click the [SD_FCXPLCR_LIB] folder and
double-click [SD_FCXPLCR_LIB.fwl] to select it.
(4) The library path inserted in the procedures above
is as follows.
{Install Folder}\LogicDesigner\Mwt\Plc\Fw_lib\
SD_FCXPLCR_LIB\SD_FCXPLCR_LIB.fwl
3.
Insert FA-M3 Emulator User Library to the new
project.
(1) Right-click [Library] under the project tree in Logic
Designer.
(2) Right-click [Insert] and select [User Library].
(3) Double-click [SD_CFAM3R_PF.mwt] to select it.
(4) The library path inserted in the procedures above
is as follows.
{Install Folder}\LogicDesigner\Libraries\
SD_CFAM3R_PF.mwt
4.
Copy a sample project POU to the new project.
(1) Open C{Install Folder}\LogicDesigner\Projects\
EXAMPLE_J.mwt.
(2) Right-click [FAM3_Emulator] in the Logic POU
under the project tree in the Example_J project,
and select [Copy].
(3) Right-click the [Logic POU] under the project tree
in the created new project, and select [Paste].
(4) Double-click the [FAM3_Emulator*] file in the
[FAM3_Emulator*] folder.
(5) For the following terminals, set as shown below.
REQ terminal
: TRUE
TERMCHAR terminal : FALSE
PORT terminal
: COM1
STATION terminal
: STATION1
5.
Defining the instance
Instantiate Logic POU. Define an already defined
instance to Task0.
(1) Right-click the [Physical hardware]
[Configuration:IPC_33/FCX01:FCX/Tasks/
Task0:CYCLIC] and select [Insert] - [Program
instance].
(2) Define the program instance name and select
FAM3_Emulator for the program type.
TRUE
REQ
VALID
VALID1
ERROR
ERROR1
STATUS1
STATUS
I
D
D
B
B
STATION1
STATION
I
D
D
B
B
I
FALSE
PORT
(Definition example of Logic POU)
TERMCHAR
COMERR1
COMERR
COMERR
COMERR1
COM1
CHECKSUM
SD_CFAM3R_OPEN_COM1
SD_CFAM3R_OPEN
(*VALID*)
(*COM1*)
FALSE
I
Содержание GOT2000Series
Страница 2: ......
Страница 17: ...A 15 REVISIONS WARRANTY...
Страница 52: ...1 30 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring...
Страница 54: ......
Страница 78: ...3 10 3 CONNECTION TO HITACHI PLC 3 6 Device Range that Can Be Set...
Страница 100: ...4 22 4 CONNECTION TO FUJI PLC 4 7 Precautions...
Страница 174: ...7 24 7 CONNECTION TO YOKOGAWA PLC 7 4 Device Range that Can Be Set...
Страница 262: ...9 54 9 CONNECTION TO RKC TEMPERATURE CONTROLLER 9 7 Precautions...
Страница 280: ...10 18 10 CONNECTION TO ALLEN BRADLEY PLC 10 4 Device Range that Can Be Set...
Страница 296: ...11 16 11 CONNECTION TO GE PLC 11 7 Precautions...
Страница 308: ...12 12 12 CONNECTION TO LS INDUSTRIAL SYSTEMS PLC 12 6 Device Range that Can Be Set...
Страница 332: ...14 18 14 CONNECTION TO SIEMENS PLC 14 4 Device Range that Can Be Set...
Страница 334: ...REVISIONS 2...
Страница 337: ......