FX Series Positioning Controllers
Program Examples 9
9-15
4) Program
5) Parameter
Set the positioning parameter No. 16 (mechanical zero point address) to "-130". For other
parameters, refer to Paragraph 9.2.4.
* When performing operation at multi-step speed in the FX
2N
-20GM, set "O0, N0" then use the
program above as it is.
In actual operation, however, the machine performs continuous pass operation, the speed
change points are different from those shown above, and the composite speed is adopted.
Line No.Instruction
Description
Ox0, N0 *
FNC02(CALL) P127;
Calls the subroutine for return to the zero point.
N1
cod00(DRV) x400 f10000;
N2
cod01(LIN) x900 f15000;
Specifies continuous passes, and adopts
operation at multi-step speed.
N3
cod01(LIN) x1700 f8000;
N4
cod01(LIN) x2000 f4000;
N5
cod01(LIN) x2300 f10000;
N6
cod09(CHK);
Confirms completion of positioning by the servo
end check, then proceeds to the next operation.
N7
cod00(DRV) x0 f10000;
N8
m02(END);
N9
P127;
Subroutine for return to the zero point.
N10
LD M9057;
N11
FNC00(CJ) P126;
Jumps to P126 if the zero point return completion
flag M9057 is ON.
N12
cod28(DRVZ);
Returns the machine to the zero point
(mechanical zero point address = -130).
N13
cod00(DRV) x0;
Moves the machine to the address "0".
N14
cod29(SETR);
Sets the electrical zero point.
N15
P126;
N16
FNC03(RET);
Subroutine return
(Specifies the end of the subroutine.)
Содержание FX2N-10GM
Страница 1: ...HARDWARE PROGRAMMING MANUAL FX2N 10GM FX2N 20GM ...
Страница 4: ...FX Series Positioning Controllers ii ...
Страница 6: ...FX Series Positioning Controllers iv ...
Страница 46: ...FX Series Positioning Controllers Introduction 1 1 34 MEMO ...
Страница 76: ...FX Series Positioning Controllers Wiring 3 3 24 MEMO ...
Страница 222: ...FX Series Positioning Controllers Operation Maintenance and Inspection 8 8 18 MEMO ...
Страница 256: ...FX Series Positioning Controllers Program Examples 9 9 34 MEMO ...