FX Series Positioning Controllers
Parameters 4
4-31
PARA. 56: General purpose input declaration for FWD/RVS/ZRN
The dedicated inputs FWD (forward rotation JOG), RVS (reverse rotation JOG) or ZRN (zero
return) can be used as general purpose inputs.
When X372 to X377 (X375 to X377 in the FX
2N
-10GM) are used for general purpose inputs in
the parameters or the programs, this parameter must be set properly.
The table below shows the details of the special auxiliary relays.
(Those for the X axis only are available in the FX
2N
-10GM.)
The table below shows the input No. when the dedicated inputs are used as general purpose
inputs. (Those for the X axis only are available in the FX
2N
-10GM.))
Table 4.52: General purpose input declaration for FWD/RVS/ZRN
Setting
FX
2N
-10GM
FX
2N
-20GM
Use X372 to X377 as
general purpose input
FWD/RVS/ZRN signal valid
Special M signal valid
0
Never
Always
Always
1
In Auto mode
Manu mode only
(not Auto mode).
Manu mode only
(not Auto mode).
2
Always
Never
Never
3
In Auto mode
Manu mode only
(not Auto mode).
Always
4
Always
Never
Always
Table 4.53: Special auxiliary relays
Details of command
X axis
Y axis
Machine zero return command
M9004
M9020
FWD JOG command
M9005
M9021
RVS JOG command
M9006
M9022
Table 4.54: General purpose inputs
Details of command
X axis
Y axis
ZRN
X375
X372
FWD
X376
X373
RVS
X377
X374
Содержание FX2N-10GM
Страница 1: ...HARDWARE PROGRAMMING MANUAL FX2N 10GM FX2N 20GM ...
Страница 4: ...FX Series Positioning Controllers ii ...
Страница 6: ...FX Series Positioning Controllers iv ...
Страница 46: ...FX Series Positioning Controllers Introduction 1 1 34 MEMO ...
Страница 76: ...FX Series Positioning Controllers Wiring 3 3 24 MEMO ...
Страница 222: ...FX Series Positioning Controllers Operation Maintenance and Inspection 8 8 18 MEMO ...
Страница 256: ...FX Series Positioning Controllers Program Examples 9 9 34 MEMO ...