FX Series Positioning Controllers
Program format 5
5-65
5.10.22 FNC90 (OUT): Output
This is an ordinary coil instruction.
When this instruction is driven with the contact turned
ON, the output is turned ON. When this instruction is
driven with the contact turned OFF, the output is
turned OFF.
FNC 90
OUT
Applicable models
Series name
Remarks
Applicable
devices
and basic
format
FNC 90
OUT
FX
2N
-10GM
FX
2N
-20GM
OUT
OUT
Output
D·
Drive
input
D·
X
Y
M
Bit devices
16-bit operation
3 steps
•
FNC 90
OUT
Y00
X00
Y00 is output if X00 is ON when the program shown on the left is
executed. Y00 is turned OFF when X00 is OFF.
If there is no contact instruction for drive input before the FNC 90
(OUT) instruction (that is, when FNC 90 instruction is directly given
from the bus), Y00 continues to be ON.
·
·