ii
[2] Transportation and Installation
Always replace a fuse with one with the cor-
rect current rating. The use of improperly
rated fuses or a substitution of fuses with
steel or copper wire may result in bursting,
fire or explosion.
To reduce the risk of electric shock, smoke,
and fire due to infiltration of dust and water,
properly install all required covers and pan-
els on the terminal box and control box.
To reduce the risk of injury from units falling
or falling over, periodically check the instal-
lation base for damage.
Consult an authorized agency for the proper
disposal of the unit. Refrigerant oil and re-
frigerant that may be left in the unit pose a
risk of fire, explosion, or environmental pol-
lution.
To reduce the risk of being caught in rotat-
ing parts, electric shock, and burns, do not
operate the unit without all required panels
and guards being installed.
To reduce the risk of injury, do not sit,
stand, or place objects on the unit.
To reduce the risk of water leakage and mal-
functions, do not turn off the power immedi-
ately after stopping operation. Leave the
unit turned on for at least 5 minutes before
turning off the power.
Do not install the unit over things that are
vulnerable to water damage from condensa-
tion dripping.
To reduce the risk of injury, electric shock,
and malfunctions, do not touch or allow ca-
bles to come in contact with the edges of
components.
To reduce the risk of injury, do not touch the
heat exchanger fins or sharp edges of com-
ponents with bare hands.
Always wear protective gears when touch-
ing electrical components on the unit. Sev-
eral minutes after the power is switched off,
residual voltage may still cause electric
shock.
To reduce the risk of electric shock and
burns, always wear protective gear when
working on units.
To reduce the risk of injury, do not insert fin-
gers or foreign objects into air inlet/outlet
grills. If the unit is left on a damaged base, it
may fall and cause injury.
To reduce the risk of injury, always wear
protective gear when working on units.
Do not release refrigerant into the atmo-
sphere. Collect and reuse the refrigerant, or
have it properly disposed of by an autho-
rized agency. Refrigerant poses environ-
mental hazards if released into the air.
Transportation and Installation
Lift the unit by placing the slings at desig-
nated locations. Support the outdoor unit
securely at four points to keep it from slip-
ping and sliding. If the unit is not properly
supported, it may fall and cause personal
injury.
To reduce the risk of injury, do not carry the
product by the PP bands that are used on
some packages.
To reduce the risk of injury, products weigh-
ing 20 kg or more should be carried by two
or more people.
Содержание PUHY-HP120TNU-A
Страница 1: ......
Страница 11: ...HWE18240_GB ...
Страница 27: ...HWE18240_GB ...
Страница 59: ...HWE18240_GB ...
Страница 69: ...HWE18240_GB ...
Страница 87: ...HWE18240_GB ...
Страница 109: ... 5 2 Outdoor Unit Control 22 chapter 5 HWE18240_GB 5 Control ...
Страница 111: ...HWE18240_GB ...
Страница 120: ...HWE18240_GB 7 9 7 Error Code 7111 70 7 9 8 Error Code 7113 71 7 9 9 Error Code 7117 72 7 9 10 Error Code 7130 73 ...
Страница 121: ...HWE18240_GB ...
Страница 195: ... 7 9 Error Code Definitions and Solutions Codes 7000 7999 74 chapter 7 HWE18240_GB 7 Troubleshooting Using Error Codes ...
Страница 279: ...HWE18240_GB ...
Страница 297: ...HWE18240_GB ...
Страница 323: ... 10 2 LED Status Indicators Table 10 LED Status Indicators on the Outdoor Unit Circuit Board 26 chapter 10 HWE18240_GB ...
Страница 324: ......