[8-9 Troubleshooting Inverter Problems ]
34
-
chapter 8
HWE18240_GB
8 Troubleshooting Based on Observed Symptoms
8-9-5
Checking the Inverter for Damage during Compressor Operation
8-9-6
Checking the Fan Motor for Ground Fault and Coil Resistance Problems
Items to be checked
Phenomena
Remedy
Put the outdoor unit into opera-
tion.
Check the inverter output volt-
age (at the compressor terminal)
after the inverter output frequen-
cy has stabilized.
<INV42Y and INV38>
1)
Overcurrent-related problems occur im-
mediately after compressor startup.
Error code : 4250
Detail code : 101, 102, 106, 107
a.
Check items [8-9-2 Checking the
Inverter Board Error Detection Cir-
cuit]through [8-9-4 Checking the
Inverter for Damage at No-
Load]for problems.
b.
Check that high and low pressures
are balanced.
c.
Check that no liquid refrigerant is
present in the compressor and that
there is no liquid backflow.
ĺ
Go to "d." when the problem per-
sists after compressor startup was
repeated several times.
d.
Check that there is a pressure dif-
ference between high and low
pressures after compressor start-
up.
ĺ
Check the high pressure with
LED monitor for changes.
Replace the compressor if there is
no pressure difference. (the com-
pressor may be locked.)
2)
There is a voltage imbalance between
the wires after the inverter output voltage
is stabilized.
Greater than the larger of the following
values: imbalance of 5% or 5V
Replace the INV board if there is a volt-
age imbalance.
Check the belt heater for problems if
there is no voltage imbalance.
ĺ
When the error occurred, liquid refrig-
erant may have been present in the
compressor.
Items to be checked
Phenomena
Remedy
Remove fan motor winding. Check
insulation resistance and coil resis-
tance.
1)
Fan motor insulation failure.
If < 1 M
ȍ
, Defect.
Change fan motor.
2)
Fan motor wire failure.
Target coil resistance: Approx. 10
ȍ
.
(Changes with temperature)
Change fan motor.
Содержание PUHY-HP120TNU-A
Страница 1: ......
Страница 11: ...HWE18240_GB ...
Страница 27: ...HWE18240_GB ...
Страница 59: ...HWE18240_GB ...
Страница 69: ...HWE18240_GB ...
Страница 87: ...HWE18240_GB ...
Страница 109: ... 5 2 Outdoor Unit Control 22 chapter 5 HWE18240_GB 5 Control ...
Страница 111: ...HWE18240_GB ...
Страница 120: ...HWE18240_GB 7 9 7 Error Code 7111 70 7 9 8 Error Code 7113 71 7 9 9 Error Code 7117 72 7 9 10 Error Code 7130 73 ...
Страница 121: ...HWE18240_GB ...
Страница 195: ... 7 9 Error Code Definitions and Solutions Codes 7000 7999 74 chapter 7 HWE18240_GB 7 Troubleshooting Using Error Codes ...
Страница 279: ...HWE18240_GB ...
Страница 297: ...HWE18240_GB ...
Страница 323: ... 10 2 LED Status Indicators Table 10 LED Status Indicators on the Outdoor Unit Circuit Board 26 chapter 10 HWE18240_GB ...
Страница 324: ......