120
5 MODULE DEDICATED INSTRUCTION
5.4 Network Dedicated Instruction
■
Slave station setting data
*1 Set the same number which was set for Number of connected modules in the control data.
*2 Setting a value outside the setting range in the setting of slave station type results in error completion of the instruction.
■
Reserved station specification data
*1 Set the parameter up to the largest station number set in the slave station setting data.
*2 Set the parameter only to the start station number of the module for the remote station/local station/intelligent device station that
occupies two or more stations.
Device
Item
Setting data
Setting
range
Setting side
(s2)[0]
(s2)[63]
Setting for 1 to
64 modules
Set the slave station type, the number of occupied slave stations, and the station
number as shown below.
Default parameter setting is '0101H to 0140H (station number: 1 to 64, number of
occupied slave stations: 1, type of slave station: Ver.1 compatible remote I/O station)'
User
Setting of station number
1 to 64 (BIN setting)
1 to 40H
Setting of the number of occupied slave stations
The setting value for the number of occupied slave stations is described below.
1H: 1 station
2H: 2 stations
3H: 3 stations
4H: 4 stations
1 to 4H
Setting of slave station type
The setting value for the slave station type is described below.
0H: Ver.1 compatible remote I/O station
1H: Ver.1 compatible remote device station
2H: Ver.1 compatible intelligent device station
5H: Ver.2 compatible single remote device station
6H: Ver.2 compatible single intelligent device station
8H: Ver.2 compatible double remote device station
9H: Ver.2 compatible double intelligent device station
BH: Ver.2 compatible quadruple remote device station
CH: Ver.2 compatible quadruple intelligent device station
EH: Ver.2 compatible octuple remote device station
FH: Ver.2 compatible octuple intelligent device station
0 to FH
Device
Item
Setting data
Setting
range
Setting side
(s3)[0]
(s3)[3]
Specification for
1 to 64
stations
Specify the reserved station.
0: Not specified
1: Specified
Default parameter setting is '0: Not specified' for all stations.
User
b15
b12 b11
b
8
b
7
b0
Stat
i
on
number
N
umber
of
occup
i
ed
T
ype
of
s
l
ave
stat
i
on
to
to
to
s
l
ave
stat
i
ons
b15
16
32
48
64
15
31
47
63
14
30
46
62
13
29
45
61
4
20
36
52
3
19
35
51
2
18
34
50
1
17
33
49
b14
b13
b12
b3
b2
b1
b0
s3 [0]
s3 [1]
s3 [2]
s3 [3]
to
to
to
to
to
1 to 64 in the table indicates a station number.
Содержание MELSEC System Q
Страница 1: ...MELSEC Q L Structured Programming Manual Special Instructions ...
Страница 2: ......
Страница 307: ...10 SFC CONTROL INSTRUCTION 10 2 SFC Transition Condition Comment Read 305 10 MEMO ...
Страница 309: ...I 307 MEMO ...
Страница 315: ......