5 MODULE DEDICATED INSTRUCTION
5.4 Network Dedicated Instruction
155
5
Setting data
Device
Item
Setting data
Setting
range
Setting side
(s1)[0]
Completion type
0 (Fixed)
0
User
(s1)[1]
Completion
status
The instruction completion status is stored.
0: Normal completion
Other than 0: Error completion (error code)
System
(s1)[2]
Host station
channel
Specify the channel of host station that stores receive data.
Setting values are as follows.
• Ethernet, MELSECNET/H, CC-Link IE Controller Network: 1 to 8
• CC-Link IE Field Network: 1 to 2
1 to 8
User
(s1)[3]
Channel used
by sending
station
Channel used by the sending station is stored.
1 to 8: Channel
System
(s1)[4]
Network No. of
sending station
Network number of the sending station is stored.
1 to 239: Network number
System
(s1)[5]
Sending station
No.
Station number of the sending station is stored.
Stored values are as follows.
• MELSECNET/H: 1 to 64
• Ethernet, CC-Link IE Controller Network: 1 to 120
• Master station in CC-Link IE Field Network: 125 (7DH)
• Slave station in CC-Link IE Field Network: 1 to 120
System
(s1)[6]
System area
(s1)[7]
(s1)[8]
(s1)[9]
Receive data
length
The number of received data stored in (s2) to (s2)+n is stored.
0: No receive data
1 to 960: Number of words of receive data
System
(s1)[10]
(s1)[17]
System area