5 MODULE DEDICATED INSTRUCTION
5.4 Network Dedicated Instruction
121
5
■
Error invalid station specification data
*1 Set the parameter up to the largest station number set in the slave station setting data.
*2 Set the parameter only to the start station number of the module for the remote station/local station/intelligent device station that
occupies two or more stations.
Reserved station specification has a priority when an error invalid station and reserved station are specified for the same station.
■
Send/receive and auto-refresh buffer assignment data
*1 Set the assignment data, in ascending order, for the stations set for a local station or intelligent device station in the slave station setting
data.
*2 Keep the total of the send/receive buffer size within 1000H (4096 (words)).
Specify the size added seven words to the size of send/receive data as the send/receive buffer size.
Setting a value outside the setting range results in error completion of the instruction.
*3 Keep the total of the auto-refresh buffer size within 1000H (4096 (words)).
Specify the necessary auto-refresh buffer size for each intelligent device station.
Setting a value outside the setting range results in error completion of the instruction.
Precautions
The RLPASET instruction is applicable to the QJ61BT11 of which the function version is B and the first five digits of the serial
number are '03042' or higher.
The QJ61BT11N and LJ61BT11 is compatible with the RLPASET instruction.
Device
Item
Setting data
Setting
range
Setting side
(s4)[0]
(s4)[3]
Specification for
1 to 64
stations
Specify the error invalid station.
0: Not specified
1: Specified
Default parameter setting is '0: Not specified' for all stations.
User
Device
Item
Setting data
Setting range
Setting side
(s5)[0]
(s5)[77]
Specification for
1 to 26
modules
Specify the buffer memory size assignment at transient
transmission for local stations and intelligent device stations.
Default parameter setting is 'send buffer size: 40H, receive buffer
size: 40H, auto-refresh buffer size: 80H'.
Send/receive buffer
: 0H (no setting) 40H to 1000H
0 (word) (no setting)
64 to 4096 (words)
Auto-refresh buffer
: 0H (no setting) 80H to 1000H
0 (word) (no setting)
128 to 4096 (words)
User
b15
16
32
48
64
15
31
47
63
14
30
46
62
13
29
45
61
to
to
to
to
4
20
36
52
3
19
35
51
2
18
34
50
1
17
33
49
b14
b13
b12
to
b3
b2
b1
b0
1 to 64 in the table indicates a station number.
s4 [0]
s4 [1]
s4 [2]
s4 [3]
Send buffer size
Receive buffer size
Auto-refresh buffer size
Send buffer size
Receive buffer size
Auto-refresh buffer size
s5 [0]
s5 [1]
s5 [2]
s5 [75]
s5 [76]
s5 [77]
Setting for the 1st module
Setting for the 26th module