1 OVERVIEW
1.2 Explanation Content in This Manual
1.2
Explanation Content in This Manual
This manual explains the programming methods and data used for control of the following modules and PID control using
structured programming technique.
• Precautions on using instructions
For details of the specifications, functions, and operating timing of each instruction, refer to the related
manuals of each module.
Function/module for explaining an
instruction
Processing performed by the instruction
Reference
Analog module
• Switches the mode. (Offset/gain setting mode or normal mode)
• Reads the user range setting offset/gain value.
• Restores the user range setting offset/gain value.
Positioning module
• Restores the absolute position of the specified axis.
• Starts positioning of the specified axis.
• Executes teaching of the specified axis.
• Writes parameters/positioning data and block start data to a flash ROM.
• Initializes setting data.
Page 39 Positioning
Instruction
Serial communication module
• Sends and receives data to and from an external device.
• Registers and reads user frames.
Page 51 Serial
Communication
Instruction
CC-Link system master/local module
• Reads and writes data from and to an intelligent device station on the CC-Link
system.
• Reads and writes data from and to the auto-refresh buffer memory at the master
station.
• Sets the network parameters.
Page 98 Network
Dedicated
Instruction
CC-Link IE network module
• Sends and receives data to and from an external device.
• Reads and writes data from and to another station on the CC-Link IE or
MELSECNET/H network system.
• Reads and clears error information.
• Sends and receives e-mails.
MELSECNET/H network module
Ethernet interface module
PID control instruction
• Sets PID control data and performs PID operation for inexact differential and exact
differential.
• Stops and starts operation of the specified loop.
• Changes the parameter of the specified loop.
Page 227 PID
CONTROL
INSTRUCTION
Socket communication function
• Opens/closes a connection.
• Reads receive data.
• Changes the receive mode.
Page 252 SOCKET
COMMUNICATION
FUNCTION
INSTRUCTION
Built-in I/O function
Positioning
function
• Starts positioning of the specified axis.
• Starts OPR of the specified axis.
• Starts JOG operation of the specified axis.
• Restores the absolute position of the specified axis.
• Stops the operating axis.
• Changes the speed and the target position of the specified axis.
Page 272 BUILT-IN
I/O FUNCTION
INSTRUCTION
Counter function
• Updates the current value of the specified CH.
• Sets a ring counter lower limit value and a ring counter upper limit value.
• Sets a preset value/latch counter value/sampling counter value.
• Sets the coincidence output No. n point.
• Measures the frequency/rotation speed.
• Stores the measured pulse value.
• Outputs the PWM wave form.
Data logging function
• Generates a trigger on the data logging of the specified data logging configuration
number.
• Resets the LOGTRG instruction of the specified data logging configuration
number.
Page 299 DATA
LOGGING
FUNCTION
INSTRUCTION
SFC control
• Reads comment of an active step in the specified SFC block.
• Reads comment of transition condition associated with an active step in the
specified SFC block.