(7) Specifying the force command value and limit value (P_FsFCd0/P_FsFCd, FSFCMD0#)
a) Force command value
Set the force command value for force control (force priority mode). Set the force command value
for each specified axis.
When force control is enabled, the robot moves so that the reactive force specified with the force
command value can be obtained.
When there is no contact (no force applied), the robot operates to the opposite direction (direction
which the specified force is generated at contact) of the force command value.
<Example>
"+10 N to Z-direction", and the tool coordinate system is set as the control coordinate system
b) Limit value
Sets the limit value for the limited stiffness control. When an external force applies on the arm tip
and the displacement occurs between the teach position and actual position while the limited
stiffness control is enabled, the robot moves to a position at which the reactive force
corresponding to the "displacement" and "stiffness coefficient" can be obtained. In the normal
stiffness control, when the stiffness coefficient or displacement is increased, the
reactive force becomes large. On the other hand, in the limited stiffness control, the force is
automatically controlled so that the reactive force does not exceed the specified limit value.
Since the limit is applied to the command value, as the value of the sensor may temporarily
exceed the limit value.
If the force sense is
enabled without
contact, the tool
moves to the specified
direction.
Maintains 10 N to the
specified direction
after contact.
P_FsFCd0 / P_FsFCd1 = (
△
,
△
,
△
,
△
,
△
,
△
,0,0)(0,0)
At force control:
△
= - (force sensor tolerance value) to + (force sensor tolerance
value)
X, Y, Z · · · [N]
A, B, C · · · [N·m]
L1, L2 · · · Not used
At limited stiffness control:
△
= 0.0 to + (force sensor tolerance value)
X, Y, Z · · · [N]
A, B, C · · · [N·m]
L1 · · · [N], L2 · · · [N·m]
P_FsFCd0=(+0.00,+0.00,+10.00,+0.00,+0.00,+0.00)(0,0)
Force command (specify 10.0 [N] for Z-axis direction)
Program example
Содержание MELFA BFP-A3614
Страница 1: ...Mitsubishi Industrial Robot Robot Seminar Textbook Force Sensor Application BFP A3614 ...
Страница 2: ......
Страница 8: ... Revision History Print Date Instruction Manual No Revision content 2018 07 31 BFP A3614 First print ...
Страница 33: ... 22 b CR800 R controller CN1 connector CR800 R controller front To OPT1 connector CPU module SSCNET III cable ...
Страница 34: ... 23 2 F series a CR750 D controller ...
Страница 35: ... 24 b CR751 D controller ...
Страница 36: ... 25 c CR750 Q CR751 Q controller CPU module ...
Страница 75: ... 64 MEMO Please use this page for your memo ...
Страница 95: ... 84 MEMO Please use this page for your memo ...
Страница 103: ... 92 MEMO Please use this page for your memo ...
Страница 111: ... 100 MEMO Please use this page for your memo ...
Страница 119: ... 108 MEMO Please use this page for your memo ...
Страница 123: ... 112 MEMO Please use this page for your memo ...
Страница 129: ... 118 MEMO Please use this page for your memo ...
Страница 133: ... 122 MEMO Please use this page for your memo ...
Страница 137: ... 126 MEMO Please use this page for your memo ...
Страница 143: ... 132 MEMO Please use this page for your memo ...
Страница 149: ... 138 MEMO Please use this page for your memo ...
Страница 153: ... 142 MEMO Please use this page for your memo ...
Страница 159: ... 148 MEMO Please use this page for your memo ...
Страница 171: ... 160 MEMO Please use this page for your memo ...
Страница 183: ... 172 MEMO Please use this page for your memo ...
Страница 191: ... 180 MEMO Please use this page for your memo ...
Страница 211: ......