-194-
Error No.
Error Cause and Remedy
First 4
Digits
Last 5
Digits
L.3986
14n00
n= Mech.
No.
Err. message Disable force sense control.
Cause
JOG operation cannot be performed on your model while the force
sense control function is enabled.
Remedy
Disable the force sense control function.
L.3986
16n00
n= Mech.
No.
Err. message Unable to perform offset cancel. (Force sense control)
Cause
It is not possible to perform offset cancel while the force sense
control function is enabled.
Remedy
If performing offset cancel, disable the force sense control
function.
L.3987
01n00
n= Mech.
No.
Err. message Force sense control is disabled.
Cause
Force sense control is disabled, and so unable to execute the
command.
Remedy
Enable the force sense control function.
L.3987
02n00
n= Mech.
No.
Err. message Force sense control is enabled.
Cause
It is not possible to enable force sense control again while already
enabled.
Remedy
First disable the force sense control function, and then enable
again.
L.3987
04n00
n= Mech.
No.
Err. message Unable to execute the FsGChg command.
Cause
It is not possible to execute the FsGChg command when force
control gain change is not complete.
Remedy
Review the program so that the FsGChg command is executed
after force control gain change is complete.
L.3987
07n00
n= Mech.
No.
Err. message Unable to output log file.
Cause
FTP processing was not properly performed.
Remedy
Check the FTP related parameter setting.
Check the Ethernet cable connection.
Check the FTP server settings at the computer.
L.3987
08n00
n= Mech.
No.
Err. message The specified log file does not exist.
Cause
The log file for the No. specified with the FsOutLog command
does not exist.
Remedy
Check whether the log file No. is incorrect.
L.3987
10n00
n= Mech.
No.
Err. message Unable to change the force sense status variable.
Cause
The status variable setting is currently being used by the force
sense control function and so cannot be changed.
Remedy
If changing the setting, disable the force sense control function.
L.3987
11n00
n= Mech.
No.
Err. message Force sense log commands executed simultaneously.
Cause
It is not possible to create/output another file while creating (FsLog
Off command) or outputting (FsOutLog command) a force sense
log file.
Remedy
Process after force sense log file creation/output is complete.
Содержание MELFA BFP-A3614
Страница 1: ...Mitsubishi Industrial Robot Robot Seminar Textbook Force Sensor Application BFP A3614 ...
Страница 2: ......
Страница 8: ... Revision History Print Date Instruction Manual No Revision content 2018 07 31 BFP A3614 First print ...
Страница 33: ... 22 b CR800 R controller CN1 connector CR800 R controller front To OPT1 connector CPU module SSCNET III cable ...
Страница 34: ... 23 2 F series a CR750 D controller ...
Страница 35: ... 24 b CR751 D controller ...
Страница 36: ... 25 c CR750 Q CR751 Q controller CPU module ...
Страница 75: ... 64 MEMO Please use this page for your memo ...
Страница 95: ... 84 MEMO Please use this page for your memo ...
Страница 103: ... 92 MEMO Please use this page for your memo ...
Страница 111: ... 100 MEMO Please use this page for your memo ...
Страница 119: ... 108 MEMO Please use this page for your memo ...
Страница 123: ... 112 MEMO Please use this page for your memo ...
Страница 129: ... 118 MEMO Please use this page for your memo ...
Страница 133: ... 122 MEMO Please use this page for your memo ...
Страница 137: ... 126 MEMO Please use this page for your memo ...
Страница 143: ... 132 MEMO Please use this page for your memo ...
Страница 149: ... 138 MEMO Please use this page for your memo ...
Страница 153: ... 142 MEMO Please use this page for your memo ...
Страница 159: ... 148 MEMO Please use this page for your memo ...
Страница 171: ... 160 MEMO Please use this page for your memo ...
Страница 183: ... 172 MEMO Please use this page for your memo ...
Страница 191: ... 180 MEMO Please use this page for your memo ...
Страница 211: ......