172
9. APPENDIX
9.1 Instruction code list
9
APPENDIX
APPENDIX provides the reference information for use of this product.
Refer to APPENDIX as required.
9.1
Instruction code list
*1
Instruction codes are used to read and write parameters in accordance with the Mitsubishi inverter protocol of RS-485 communication. (For RS-
485 communication, refer to
*2
For Parameter copy, Parameter clear, and All parameter clear,
○
indicates the function is available, and × indicates the function is not available.
*3
Communication parameters that are not cleared by Parameter clear (All parameter clear) via the RS-485 communication. (For RS-485
communication, refer to
*4
Reading and writing via the PU connector are available.
Pr.
Name
Instruction
code
Parameter
Read
Writ
e
Extended
Cop
y
Clear
All cl
ear
30
Reset selection during
power supply to main
circuit
1E
9E
0
○
○
○
57
Restart selection
39
B9
0
○
○
○
65
Retry selection
41
C1
0
○
○
○
67
Number of retries at
fault occurrence
43
C3
0
○
○
○
68
Retry waiting time
44
C4
0
○
○
○
69
Retry count display
erase
45
C5
0
○
○
○
75
Reset selection/
disconnected PU
detection/reset limit
4B
CB
0
○
×
×
Parameter write
selection
4D CD
0
○
○
○
117
PU communication
station number
11
91
1
○
○
○
118
PU communication
speed
12
92
1
○
○
○
119
PU communication
stop bit length / data
length
13
93
1
○
○
○
120
PU communication
parity check
14
94
1
○
○
○
121
PU communication
retry count
15
95
1
○
○
○
122
PU communication
check time interval
16
96
1
○
○
○
123
PU communication
waiting time setting
17
97
1
○
○
○
124
PU communication
CR/LF selection
18
98
1
○
○
○
161
Key lock operation
selection
01
81
2
○
×
○
168
Parameter for manufacturer setting. Do not set.
169
170
Watt-hour meter clear
0A
8A
2
○
×
○
178
RDI terminal function
selection
12
92
2
○
×
○
187
OH terminal function
selection
1B
9B
2
○
×
○
189
RES terminal function
selection
1D
9D
2
○
×
○
190
RDB terminal function
selection
1E
9E
2
○
×
○
191
RDA terminal function
selection
1F
9F
2
○
×
○
192
IPF terminal function
selection
20
A0
2
○
×
○
193
RSO terminal function
selection
21
A1
2
○
×
○
194
FAN terminal function
selection
22
A2
2
○
×
○
195
ABC1 terminal function
selection
23
A3
2
○
×
○
248
Self power
management selection
38
B8
2
○
○
○
255
Life alarm status
display
3F
BF
2
×
×
×
256
Inrush current limit
circuit life display
40
C0
2
×
×
×
257
Control circuit
capacitor life display
41
C1
2
×
×
×
261
Power failure stop
selection
45
C5
2
○
○
○
268
Monitor decimal digits
selection
4C CC
2
○
○
○
269
Parameter for manufacturer setting. Do not set.
290
Monitor negative
output selection
62
E2
2
○
○
○
296
Password lock level
68
E8
2
○
×
○
297
Password lock/unlock
69
E9
2
○
○
331
RS-485
communication station
number
1F
9F
3
○
○
332
RS-485
communication speed
20
A0
3
○
○
333
RS-485
communication stop bit
length / data length
21
A1
3
○
○
334
RS-485
communication parity
check selection
22
A2
3
○
○
Pr.
Name
Instruction
code
*1
Parameter
Read
Writ
e
Extended
Cop
y
*2
Clear
*2
All c
lear
*2
Содержание FR-CC2-N Series
Страница 61: ...60 3 PRECAUTIONS FOR USE OF THE CONVERTER UNIT 3 4 Checklist before starting operation MEMO ...
Страница 137: ...136 5 PARAMETERS 5 10 Checking parameters changed from their initial values initial value change list MEMO ...
Страница 153: ...152 6 PROTECTIVE FUNCTIONS 6 6 Check first when you have a trouble MEMO ...
Страница 165: ...164 7 PRECAUTIONS FOR MAINTENANCE AND INSPECTION 7 2 Measurement of main circuit voltages currents and powers MEMO ...
Страница 171: ...170 8 SPECIFICATIONS 8 3 Outline dimension drawings MEMO ...