69
5. PARAMETERS
5.1 Parameter List
1
2
3
4
5
6
7
8
9
10
178
T700
RDI terminal function selection
7, 62, 9999
1
9999
187
T709
OH terminal function selection
1
7
189
T711
RES terminal function selection
1
62
190
M400
RDB terminal function selection
2, 8, 11, 17, 25, 26, 64, 68,
90, 94, 95, 98, 99, 102,
108, 111, 125, 126, 164,
168, 190, 194, 195, 198,
199, 206, 207, 209, 210,
214, 306, 307, 309, 310,
9999
1
111
191
M401
RDA terminal function selection
1
11
192
M402
IPF terminal function selection
1
2
193
M403
RSO terminal function selection
1
209
194
M404
FAN terminal function selection
1
25
195
M405
ABC1 terminal function selection
1
99
248
A006
Self power management selection
0, 1, 2
1
0
255
E700
Life alarm status display
(0 to 15)
1
0
256
E701
Inrush current limit circuit life
display
(0 to 100%)
1%
100%
257
E702
Control circuit capacitor life
display
(0 to 100%)
1%
100%
261
A730
Power failure stop selection
0, 1, 2, 21, 22
1
0
268
M022
Monitor decimal digits selection
0, 1, 9999
1
9999
269
E023
Parameter for manufacturer setting. Do not set.
290
M044
Monitor negative output selection
0, 2, 4, 6
1
0
296
E410
Password lock level
0 to 3, 5, 6, 100 to 103,
105, 106, 9999
1
9999
297
E411
Password lock/unlock
(0 to 5), 1000 to 9998,
9999
1
9999
331
N030
RS-485 communication station
number
0 to 31 (0 to 247)
1
0
332
N031
RS-485 communication speed
3, 6, 12, 24, 48, 96, 192,
384, 576, 768, 1152
1
96
333
—
RS-485 communication stop bit
length / data length
0, 1, 10, 11
1
1
N032
RS-485 communication data length
0, 1
1
0
N033
RS-485 communication stop bit
length
0, 1
1
1
334
N034
RS-485 communication parity
check selection
0 to 2
1
2
335
N035
RS-485 communication retry count
0 to 10, 9999
1
1
336
N036
RS-485 communication check time
interval
0 to 999.8 s, 9999
0.1 s
0 s
337
N037
RS-485 communication waiting
time setting
0 to 150 ms, 9999
1 ms
9999
341
N038
RS-485 communication CR/LF
selection
0 to 2
1
1
342
N001
Communication EEPROM write
selection
0, 1
1
0
343
N080
Communication error count
—
1
0
503
E710
Maintenance timer 1
0 (1 to 9998)
1
0
504
E711
Maintenance timer 1 warning
output set time
0 to 9998, 9999
1
9999
539
N002
MODBUS RTU communication
check time interval
0 to 999.8 s, 9999
0.1 s
9999
549
N000
Protocol selection
0, 1
1
0
563
M021
Energization time carrying-over
times
(0 to 65535)
1
0
663
M060
Control circuit temperature signal
output level
0°C to 100°C
1°C
0°C
686
E712
Maintenance timer 2
0 (1 to 9998)
1
0
687
E713
Maintenance timer 2 warning
output set time
0 to 9998, 9999
1
9999
688
E714
Maintenance timer 3
0 (1 to 9998)
1
0
689
E715
Maintenance timer 3 warning
output set time
0 to 9998, 9999
1
9999
Pr.
Pr.
group
Name
Setting range
Minimum
setting
increments
Initial
value
Refer to
page
Customer
setting
Содержание FR-CC2-N Series
Страница 61: ...60 3 PRECAUTIONS FOR USE OF THE CONVERTER UNIT 3 4 Checklist before starting operation MEMO ...
Страница 137: ...136 5 PARAMETERS 5 10 Checking parameters changed from their initial values initial value change list MEMO ...
Страница 153: ...152 6 PROTECTIVE FUNCTIONS 6 6 Check first when you have a trouble MEMO ...
Страница 165: ...164 7 PRECAUTIONS FOR MAINTENANCE AND INSPECTION 7 2 Measurement of main circuit voltages currents and powers MEMO ...
Страница 171: ...170 8 SPECIFICATIONS 8 3 Outline dimension drawings MEMO ...