4. PARAMETERS FOR POSITIONING CONTROL
4
−
9
4.3.2 MR- -B servo parameters
The servo parameters to be set are indicated in Tables 4.4 through 4.6.
(1) Basic parameters
For the servo parameters of the MR-J2S-B, refer to the "SSCNET-Compatible
MR-J2S- B Servo Amplifier Instruction Manual (SH-030001).
Table 4.4 Servo Parameters (Basic Parameters)
Setting Range
Default
mm
inch
degree
PULSE
No.
Item
Setting
Range
Units
Setting
Range
Units
Setting
Range
Units
Setting
Range
Units
Initial
Value
Units
Remarks
Expla-
natory
Section
(Note)
1
Amplifier
setting
(Note)
2
Regenerati-
ve resistor
(Note)
3
External
dynamic
brake
(Note)
4
Motor type
(Note)
5
Motor
capacity
6
Number of
motor
revolution
(R)
7
Number of
feedback
pulses (N)
Set automatically in accordance with the system settings.
APP. 5
8
Rotating
direction
0: Forward rotation (CCW) when the positioning address increases.
1: Reverse rotation (CW) when the positioning address decreases.
0
•
Set the direction of rotation
as seen from the load side.
Forward rotation:
reverse rotation:
9
Automatic
tuning
0: Speed only
1: Position/speed
2: Not executed
1
•
Set the gain
(speed/position, speed) for
executing automatic setting.
4.3.9
10
Servo
responsive
-ness
1 to 12
1
•
Set in order to increase
servo responsiveness.
4.3.10
(Note-1) : After changing any of the items marked "Note" in the table above, turn the servo
power supply on after resetting the servo system CPU with the key switch or