(2) The JOG operation signal, JOG operation setting register, and setting range for
each axis are shown in the table below.
JOG Operation
JOG Operation Setting Register
mm
inch
degree
PULSE
No.
Forward
JOG
Reverse
JOG
Most
Significant
Least
Significant
Setting
Range
Units
Setting
Range
Units
Setting
Range
Units
Setting
Range
Units
1
M3202
M3203
D641
D640
2
M3222
M3223
D643
D642
3
M3242
M3243
D645
D644
4
M3262
M3263
D647
D646
5
M3282
M3283
D649
D648
6
M3302
M3303
D651
D650
7
M3322
M3323
D653
D652
8
M3342
M3343
D655
D654
9
M3362
M3363
D657
D656
10
M3382
M3383
D659
D658
11
M3402
M3403
D661
D660
12
M3422
M3423
D663
D662
13
M3442
M3443
D665
D664
14
M3462
M3463
D667
D666
15
M3482
M3483
D669
D668
16
M3502
M3503
D671
D670
17
M3522
M3523
D673
D672
18
M3542
M3543
D675
D674
19
M3562
M3563
D677
D676
20
M3582
M3583
D679
D678
21
M3602
M3603
D681
D680
22
M3622
M3623
D683
D682
23
M3642
M3643
D685
D684
24
M3662
M3663
D687
D686
25
M3682
M3683
D689
D688
26
M3702
M3703
D691
D690
27
M3722
M3723
D693
D692
28
M3742
M3743
D695
D694
29
M3762
M3763
D697
D696
30
M3782
M3783
D699
D698
31
M3802
M3803
D701
D700
32
M3822
M3823
D703
D702
1 to
600000000
10
-2
mm/
min
1 to
600000000
10
-3
inch/
min
1 to
2147483647
10
-3
degree
/min
1 to
10000000
PLS/s
POINT
To set the JOG operation speed using a sequence program, store a value in
the JOG operation speed setting register which is 100 times the real speed in
units of millimeters or 1000 times the speed in units of inches or degrees.
To set a JOG operation speed of 6000.00 mm/min., store the value
600000 in the JOG operation speed setting register.
Example