![Mitsubishi Electric A173UHCPU Скачать руководство пользователя страница 236](http://html.mh-extra.com/html/mitsubishi-electric/a173uhcpu/a173uhcpu_programming-manual_238567236.webp)
7. POSITIONING CONTROL
7
−
89
(3) Operation timing and speed-switching positions
The operation timing for speed-switching control and the speed-switching
points are shown below.
Axis 2
positioning
direction
Axis 3 positioning direction
50000
100000
50000
t
V
50000
200000
150000
All axes servo start command (M2042)
All axes servo start accept flag(M2049)
Start command (X000)
SVST instruction
Axis 2 start accept flag(M2002)
PLC ready(M2000)
Axis 3 start accept flag(M2003)
100000